检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈金良 李秀[2] 王雪亮[1,3] CHEN Jin-liang;LI Xiu;WANG Xue-liang(School of Civil Engineering and Architecture,Wuhan University of Technology,Wuhan 430070,China;School of Architecture and Engineering,Wuhan Polytechnic,Wuhan 430074,China;Hainan Research Institute,Wuhan University of Technology,Sanya 572025,China)
机构地区:[1]武汉理工大学土木工程与建筑学院,武汉430070 [2]武汉职业技术学院建筑工程学院,武汉430074 [3]武汉理工大学海南研究所,三亚572025
出 处:《武汉理工大学学报》2023年第1期64-70,共7页Journal of Wuhan University of Technology
基 金:海南省科技计划三亚崖州湾科技城联合项目(520LH058);海南省自然科学基金(522MS096);湖北省自科基金(ZRMS2018001785)。
摘 要:为探究胶合木框架结构抗侧刚度的影响因素,推导了三层半刚接结构框架的抗侧刚度的计算公式,确定了框架抗侧刚度与节点刚度、柱线刚度和梁线刚度的关系,并对采用不同的柱截面尺寸和节点刚度的框架结构进行了有限元模拟。结果表明:节点刚度与柱线刚度是影响结构抗侧刚度的主要因素,抗侧刚度随着节点刚度和柱线刚度的增加而增大;柱截面尺寸较小时,节点刚度对结构抗侧刚度的影响显著,是提高结构抗侧刚度的有效手段;节点刚度较小时,柱截面尺寸对结构抗侧刚度的影响也较明显,但不够经济。该研究成果可为胶合木结构设计提供一定参考。In order to explore the influencing factors of the lateral stiffness of glued timber frame structure, the calculation formula of the lateral stiffness of the three-story semi-rigid frame structure was deduced, the relationship between the lateral stiffness of the frame and the joint stiffness, column line stiffness and beam line stiffness was determined.The frame structure with different column cross section and joint stiffness was simulated by finite element method.The results show that the joint stiffness and column line stiffness are the main factors affecting the lateral stiffness of the structure, and the lateral stiffness increases with the increase of joint stiffness and column line stiffness.When the column cross section is small, the joint stiffness has a significant impact on the lateral stiffness of the structure, which is an effective method to improve the structural lateral stiffness.When the joint stiffness is small, the influence of column cross section on the lateral stiffness of the structure is also obvious, but it is not economical.The research results can provide some reference for the design of glued timber structure.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.17.176.160