作  者:黄国兴 林一庚 康红梅 王志滨[2] 彭桂瀚[2] 姚保民 HUANG Guoxing;LIN Yigeng;KANG Hongmei;WANG Zhibin;PENG Guihan;YAO Baomin(Fuzhou City Construction Design and Research Institute Co.,Ltd.,Fuzhou,Fujian 350001,China;College of Civil Engineering,Fuzhou University,Fuzhou,Fujian 350108,China;China Nuclear Industry 24 Construction Co.,Ltd.,Mianyang,Sichuan 621000,China)

机构地区:[1]福州城建设计研究院有限公司,福建福州350001 [2]福州大学土木工程学院,福建福州350108 [3]中国核工业二四建设有限公司,四川绵阳621000

出  处:《福州大学学报(自然科学版)》2023年第2期171-177,共7页Journal of Fuzhou University(Natural Science Edition)

基  金:国家自然科学基金资助项目(52178122)。

摘  要:以钢管壁厚、钢管屈服强度、碳纤维增强聚合物(carbon fiber reinforced polymer,CFRP)层数和位置、混凝土强度等为研究参数,进行19根CFRP-钢管-CFRP复合钢管约束海砂混凝土短柱的轴压试验,分析试件破坏模式、荷载-应变曲线、结构承载力等,并讨论现有算法对承载力计算的适用性.研究结果表明:内外壁CFRP与钢管的组合对核心混凝土有良好的复合约束作用,可大幅提高结构承载力;钢管内外壁张贴CFRP后,其结构破坏模式由剪切破坏变为腰鼓破坏;钢管最先开始屈服,CFRP层数决定纤维布的断裂宽度和分布;荷载-应变曲线在强化阶段呈明显线性上升特性,二次刚度由CFRP层数决定;与外壁张贴CFRP试件相比,内壁张贴CFRP试件的结构承载力更大.19 sea sand concrete-filled CFRP-steel-CFRP composite steel tubular stub columns under axial loads are tested by taking the steel tube wall thickness,yield strength,CFRP layers and loca­tion,and concrete strength as research parameters.The failure modes of specimen,load-strain rela­tions and bearing capacity are analyzed.The applicability of existing algorithms to bearing capacity is also discussed.The results show that the combination of CFRP and steel tube performs a good restraint effect to core concrete and can greatly improve the structural bearing capacity.The failure mode of the structure is changed from shear failure to waist drum failure when CFRP layers are bonded on the inner and outer walls of the steel tube.The steel tube is the first to yield and the number of the CFRP layers determines the fracture width and distribution of the fiber cloth.The load-strain curve shows an obvious linear rise during the strengthening stage.The secondary stiffness is determined by the number of the CFRP layers.The structural bearing capacity of CFRP bonding on inner wall is larger than that of CFRP bonding on outer wall.

关 键 词:复合钢管 碳纤维增强聚合物 承载力 短柱 轴压 

分 类 号:TU398[建筑科学—结构工程] TU317.1

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象