检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵宝山 刘明 赵传志 马永杰 魏海鸿 上官瑞凯 ZHAO Baoshan;LIU Ming;ZHAO Chuanzhi;MA Yongjie;WEI Haihong;SHANGGUAN Ruikai(SPIC Shanxi New Energy Co.,Ltd.,Xi’an 710000)
机构地区:[1]国投陕西新能源有限公司,陕西西安710000
出 处:《电力安全技术》2023年第3期49-52,共4页Electric Safety Technology
摘 要:绝缘栅双极型晶体管(IGBT)功率模块作为逆变器的核心元件,其可靠性直接关系到光伏电站的安全运行。通过IGBT功率模块频繁损坏的原因分析,从运行环境、硬件、软件以及板件自身等方面提出相应的改进措施并取得一定的成效,相关经验可供解决逆变器故障参考。Insulated gate bipolar transistor(IGBT)power module is the core components of inverter.Its reliability is directly related to the safe operation of photovoltaic power station.By analysis on the causes of frequent damages of IGBT power module,the corresponding improvement measures are put forward from the aspects of operating environment,hardware,software and board itself with good practice achieved.The relevant experience is regarded as the reference for dealing with inverter faults.