检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:袁可 陈晓亮 任小梅 周俊 代汉莉 YUAN Ke;CHEN Xiaoliang;REN Xiaomei(Clinical Laboratory,Wuhan No.9 Hospital,Hubei Wuhan 430081)
机构地区:[1]武汉市第九医院检验科,湖北武汉430281 [2]感染性疾病与肿瘤基因诊断技术国家地方联合工程研究中心,湖南长沙410002
出 处:《医学检验与临床》2023年第2期16-19,46,共5页Medical Laboratory Science and Clinics
摘 要:目的:考察及评价多重PCR联检试剂在社区获得性肺炎(CAP)的临床诊断性能和应用价值。方法:同时用多重PCR联检试剂和肺炎支原体单检试剂检测采集727例有呼吸道感染症状的患者咽拭子样本,比较分析两种试剂的灵敏度、结果一致性和相关性,对于重点关注的患者进行治疗监测。结果:727例样本PCR联检试剂和单检试剂检测结果的阳性一致性为97.69%,阴性一致性为99.66%,总一致性为99.31%,其中阴阳性不符合的5例标本,两种检测试剂诊断一致非常高(κ=0.9765,P<0.0001);在127例肺炎支原体阳性样本中,联检试剂检出了6例流感病毒或呼吸道合胞病毒混合感染病例,在疗效监测中发现单一病原体检测结果对于用药指导信息可能不够充足。结论:多重PCR技术可以在实验检测中一次性检测多种病原体,且具备单检试剂的检测性能,对于多重病原体感染有着一定的临床意义。Objective:To investigate and evaluate a multiplex PCR reagent's in clinical diagnostic performance and application value for community-acquired pneumonia(CAP).Methods:the pharyngeal swab samples of 727 patients with respiratory tract infection were collected by simultaneous detection of multiple PCR The sensitivity,specificity accuracy,of the two reagents were compared and analyzed.The treatment process of co-infection patients was recorded.Results:The positive consistency of multiplex PCR reagent and single test reagent was 97.69%,the negative consistency was 99.66%,and the total consistency was 99.31%(κ=0.9765,P<0.0001);Among 127 positive samples of Mycoplasma pneumoniae,6 cases of mixed infection of influenza virus or respiratory syncytial virus were detected by the multiplex PCR reagent.The detection results of single pathogen may not be sufficient for medication guidance.Conclusion:Multiplex PCR technology has the same performance as the single detection reagent and could detect various pathogens in one experiment,which is the essential clinical significance for pathogen co-infections.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.129.134