RPIR+磁混凝工艺在污水处理厂提标改造中的应用  被引量:4

Application of RPIR+Magnetic Coagulation Process in Upgrading and Reconstruction WWTP

在线阅读下载全文

作  者:彭东升 许洋 李方源 张扬 张建建 尹娟 李红桔 PENG Dongsheng;XU Yang;LI Fangyuan;ZHANG Yang;ZHANG Jianjian;YIN Juan;LI Hongju(Shenzhen Guanghuiyuan Environmental Water Co.,Ltd.,Shenzhen 518011,China;Qingyan Environmental Technology Co.,Ltd.,Shenzhen 518057,China)

机构地区:[1]深圳市广汇源环境水务有限公司,广东深圳518011 [2]清研环境科技股份有限公司,广东深圳518057

出  处:《净水技术》2023年第3期158-163,共6页Water Purification Technology

摘  要:深圳市某污水处理厂原处理规模为2.5万m^(3)/d,采用接触氧化处理工艺,设计出水执行《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准(TN、TP除外)。为满足更加严格的水质考核要求,需对污水处理厂进行提标改造,使出水水质指标满足《地表水环境质量标准》(GB 3838—2002)IV类标准(TN除外,SS采用原标准)。提标改造工程根据处理需求并结合各构筑物运行工况,处理规模调整为2万m^(3)/d,改造采用以快速生化污水处理技术(RPIR)+磁混凝沉淀为核心的处理工艺。项目改造后运行稳定,出水水质全面优于设计出水水质标准。此外,污水处理厂提标改造成本按日均污水量计算为1481.16元/m^(3),直接运行成本仅提高0.28元/m^(3)。The treatment scale of a wastewater treatment plant(WWTP)in Shenzhen City is 2.5×10^(4) m^(3)/d,the contact oxidation treatment process is adopted,and the original designed effluent complies with the first class A criteria of Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918—2002)(except TN and TP).In order to meet the more stringent requirements of water quality assessment,the WWTP needs to be upgraded and the effluent shall comply with classⅣstandard of the Environmental Quality Standard for Surface Water(GB 3838—2002)(except TN,SS adopts the original standard).According to the treatment needs and the operating conditions of the WWTP at the current stage,the upgrading and renovation project has adjusted the treatment scale to 2×10^(4)m^(3)/d,and determine to use the rapid purification of wastewater using sedimentation integrated rectangular airlift loop reactor(RPIR)+magnetic coagulation sedimentation transformation process to improve the effluent quality.The effluent is stably even better than the the standard after the transformation.In addition,the cost of upgrading and upgrading the WWTP is calculated at 1481.16 yuan/m^(3)based on the average daily wastewater volume,and the direct operating cost is increased by 0.28 yuan/m^(3).

关 键 词:污水处理厂 提标改造 快速生化污水处理技术 磁混凝 运行分析 

分 类 号:TU992[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象