铜表面态对三唑类点击组装膜在电厂循环冷却水中对铜的保护性能的影响  被引量:1

Effect of Copper Surface State on the Protective Performance of Triazole Click⁃Assembly Film on Copper in Circulating Cooling Water of Power Plant

在线阅读下载全文

作  者:朱才超 李瑾 张大全 ZHU Cai-chao;LI Jin;ZHANG Da-quan(Shanghai Key Laboratory of Power Material Protection and New Materials,Shanghai Electric Power University,Shanghai 200090,China;School of Environmental and Chemical Engineering,Shanghai Electric Power University,Shanghai 200090,China)

机构地区:[1]上海电力大学上海市电力材料防护与新材料重点实验室,上海200090 [2]上海电力大学环境与化学工程学院,上海200090

出  处:《材料保护》2023年第3期106-113,共8页Materials Protection

基  金:国家自然科学基金项目(52001194,51571140)资助。

摘  要:为了研究不同铜表面态对三唑类点击组装膜在电厂循环冷却水中对铜的保护性能的影响,以对甲苯基磺酰叠氮(MA)、丙炔酸(PR)作为组装单元,采用原位点击组装法在不同铜表面态上形成三唑缓蚀膜(CuMA-PR、Cu_(2)O^(MA-PR)、CuO_(MA-PR))。采用电化学方法、腐蚀挂片法、SEM表征及抗菌性能分析评估了三唑缓蚀膜对铜基体的缓蚀性能,同时,考察了Cu_(2)OMA-PR在电厂循环冷却水体系中对铜基体的保护效果。结果表明:Cu_(2)O表面态最有利于三唑缓蚀膜的形成(Cu_(2)OMA-PR),Cu_(2)O^(MA-PR)在21 d内对铜基体具有良好的缓蚀作用和抗菌效果,其在21 d内对铜的平均缓蚀率为85.4%,同时可有效抑制各类微生物菌群的繁殖。In order to investigate the effect of different copper surface state on the protection performance of triazole click⁃assembly film on Cu in circulating cooling water of power plants,the triazole inhibition films(Cu_(MA-PR),Cu_(2)O_(MA-PR),CuO _(MA-PR))were prepared via an in⁃situ click assembling reaction using p⁃toluenesulfonyl azide(MA)and propionic acid(PR)as assembly units on different copper surface state.Corrosion inhibition performance of the triazole inhibition films on copper substrate was evaluated by electrochemical method,corrosion coupon testing,SEM characterization and antibacterial property analysis.At the same time,the protective effect of Cu_(2)O_(MA-PR) on copper substrate in the circulating cooling water system of power plant was investigated.Results showed that Cu_(2)O surface state was the best for the formation of triazole inhibition film(Cu_(2)O_(MA-PR)).The Cu_(2)O_(MA-PR) exhibited an excellent corrosion inhibition and antibacterial property on copper substrate within 21 d.The average inhibition efficiency of Cu_(2)O_(MA-PR) for copper in 3 weeks was 85.4%.Besides,Cu _(2)O_(MA-PR) could also effectively inhibit the proliferation of various microbial communities.

关 键 词:铜表面态 三唑 点击组装 缓蚀抗菌 循环冷却水 

分 类 号:TG174.42[金属学及工艺—金属表面处理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象