摘 要:为精准、定量地计算交直流混联受端电网遭受短路故障后,电压恢复至正常运行水平的能力,提出了基于直流逆变站交流母线电压和熄弧角关键特征的受端电网电压弹性评估方法。首先,建立考虑多短路故障的交直流混联受端电网电压弹性评估模型,以故障后电压恢复标准为约束,提出同时计及逆变站交流母线电压和熄弧角变化特征的电压弹性评估指标;然后,基于潮流计算和机电暂态仿真实现上述评估模型的求解;最后,以江苏电网多种运行方式为例进行仿真验证,结果表明文中提出的方法可用于实际电网电压恢复能力的精准评估,并实现不同运行方式下电压弹性恢复力的量化计算。For accurately and quantitatively calculating the ability of the voltage recovers to normal operation level after the AC/DC hybrid receiving⁃end power grid suffers from short circuit fault,a kind of voltage⁃resilience assess⁃ment method of the receiving⁃end power grid based on key characteristic of AC busbar voltage and extinction angle of DC inverter station is proposed.Firstly,voltage⁃resilience assessment model of AC/DC hybrid receiving⁃end power grid considering multiple short circuit fault is set up.Then,with the voltage recovery standard after the fault as the constraints,the voltage⁃resilience assessment index considering simultaneously variation characteristic of AC busbar voltage and extinction angle of inverter station is proposed.After that,the solution of above assessment model is achieved on the basis of power flow calculation and electromechanical transient simulation.Finally,the multiple oper⁃ation modes of Jiangsu Power Grid is used as an example for simulation verification.The result shows that the method proposed in this paper can be used for precision assessment of voltage recovery ability of actual power grid,and can achieve the quantitative calculation of voltage⁃esilience recovery under different operation modes.
分 类 号:TM721.3[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49