摘  要:主要论述了配电变压器低压侧0.4 kV进线断路器的保护定值整定方法和应用。基于三段式保护设定方法,论证了取消速断保护的必要性,详解给出了选择性速断保护和过载保护的整定计算原则。通过实例计算和实际应用验证了0.4 kV进线断路器的保护定值整定方法的正确性。The protection setting method and application of 0.4 kV incoming circuit breaker at the low voltage side of distribution transformer are mainly discussed.Based on the three-section protection setting method,the necessity of canceling quick-break protection is demonstrated,and the setting calculation principles of selective quick-break protection and overload protection are given in detail.The correctness of the protection setting method of 0.4 kV incoming circuit breaker is verified by case calculation and practical application.