作 者:刘黄 郑楠 赵晓辉 魏进家[1] Huang LIU;Nan ZHENG;Xiaohui ZHAO;Jinjia WEI(School of Chemical Engineering and Technology,Xi'an Jiaotong University,Xi'an,Shaanxi 710049,China;Northwest Electric Power Design Institute Co.,Ltd.of CPECC,Xi'an,Shaanxi 710075,China)
机构地区:[1]西安交通大学化学工程与技术学院,陕西西安710049 [2]中国电力工程顾问集团西北电力设计院有限公司,陕西西安710075
出 处:《过程工程学报》2023年第2期216-225,共10页The Chinese Journal of Process Engineering
基 金:国家重点研发计划(编号:2018YFB1501003)。
摘 要:针对含内埋管的3维浅层流化床,以空气和非均匀铝矾土铸造砂颗粒为气相和固相开展冷态实验,采用压差变送器测量了5种不同开孔率布风板的床层压降,考察了开孔率、静床高度及流化仓室配风模式对非均匀颗粒流态化特征参数及流化质量的影响。结果表明,非均匀颗粒的床层压降特性曲线不存在明显的突变,流化过程分为固定床、半流态化和完全流态化三个阶段,各阶段分界点特征速度受开孔率影响不大。对于平均粒径为215μm的非均匀颗粒,床层压降标准差随开孔率的变化存在极小值,开孔率为0.79%的布风板流态化稳定性最高。配风模式对多仓室流化床局部床层压降有重要影响,采用等风速模式可有效降低仓室之间的压降差异,提高整体流化空间的均匀性。In the next generation high-temperature solar thermal power system,solid particles are the dominant heat absorbing fluid.Special heat exchangers need to be developed for the energy transmission between particles and other functional thermal fluids,considering the poor fluidity of solid particles.Shallow fluidized bed with immersed pipes is a no promising technology for extracting heat from highit c Various a r F open area temperature particles.However,there is still a lack of ratio unanimous criteria for the optimization design of such devices,Diameter Controlled air flow Non-homogeneous particles especially when non-homogeneous particles with great economic benefits are used.As the first step in the research and design program,the fluidization characteristics of polydisperse bauxite particles in a three dimensional shallow fluidized-bed with built-in tubes were investigated via cold state experiments.Bed pressure drops were measured under five different perforated plate distributor with a range of open area ratio from 0.38% to 2.89%.The effects of open area ratio,static bed height and air distribution mode on the characteristic parameters and quality of the fluidization were also investigated.The results showed that there was no obvious abrupt change in the bed pressure drop curve of the non-homogeneous particles,and the whole process could be divided into three stages:fixed bed,semi-fluidization and complete fluidization.The open area ratio had little influence on the characteristic velocities at the boundary of two adjacent stages.For the concerned non-homogeneous particles,the change of standard deviation of bed pressure drop showed a minimum value,and the fluidization stability became the highest when plate with an opening area ratio of 0.79% was used.The air distribution mode has an important influence on the local bed pressure drop in the multi-chamber fluidized bed.The uniform velocity mode could effectively reduce the pressure drop difference between chambers and improve the uniformity of the overall flu
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222