在线阅读下载全文

作  者:张正春 王伟[2] 石红 ZHANG Zheng-chun;WANG Wei;SHI Hong(Shanghai Ivco Valve Co.,Ltd.,Shanghai 201799,China;Suzhou Thermal Engineering Research Institute Co.,Ltd.,Suzhou 215004,Jiangsu,China;Center for Nuclear and Radiation Safety,Ministry of Ecology and Environment,Beijing 100082,China)

机构地区:[1]上海艾维科阀门股份有限公司,上海201799 [2]苏州热工研究院有限公司,江苏苏州215004 [3]生态环境部核与辐射安全中心,北京100082

出  处:《阀门》2023年第2期169-174,共6页VALVE MAGAZINE

摘  要:根据核安全规范抗震I类设备的抗震试验鉴定要求,利用液压振动台、电动振动台试验系统,模拟SSE地震运动水平,对运行于CAP1400型压水堆核电机组中的核级高压气体减压阀进行抗震试验,验证其完整性和可运行性。试验结果表明:核级减压阀的固有频率、振动老化、静态加载和RIM动态地震的测试项均符合抗震鉴定要求。本文抗震鉴定试验法综合验证了SSE地震工况下核级减压阀的抗震性能,同时验证了抗震计算方法的正确性,该方法亦可为核电厂类似的抗震鉴定实践活动提供有益借鉴。In this paper,according to the seismic test and identification requirements of seismic class I e-quipment in the nuclear safety code,using the hydraulic shaking table and electric shaking table test system to simulate the SSE seismic movement level,the seismic test of the nuclear grade high-pressure gas pressure reducing valve operating in the CAP 1400 PWR nuclear motor unit is carried out to verify its integrity and operability.The test results show that the test items of natural frequency,vibration aging,static loading and rim dynamic earthquake of nuclear grade pressure reducing valve meet the requirements of seismic evaluation.The seismic evaluation test method in this paper comprehensively verifies the seismic performance of nuclear grade pressure reducing valve under SSE seismic conditions,and verifies the correctness of seismic calculation method.This method can also provide a useful reference for similar seismic evaluation practice of nuclear power plant.

关 键 词:核级高压气体减压阀 抗震鉴定试验 固有频率 振动老化 RIM地震试验 

分 类 号:TH134[机械工程—机械制造及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象