检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:原长锁 张宁 鞠晨 曹举 贺博[2] YUAN Changsuo;ZHANG Ning;JU Chen;CAO Ju;HE bo(CHN Energy Shendong Coal Group Technology Research Institute,Yulin 719315,China;School of Electrical Engineering,Xi’an Jiaotong University,Xi’an 710049,China;Clean Power Development Project Department of Changqing Oilfield Branch,Xi’an 710200,China)
机构地区:[1]国能神东煤炭集团技术研究院,榆林719315 [2]西安交通大学电气工程学院,西安710049 [3]长庆油田分公司清洁电力开发项目部,西安710200
出 处:《西安工业大学学报》2023年第2期171-179,共9页Journal of Xi’an Technological University
基 金:国家自然科学基金青年基金项目(51107095)。
摘 要:针对变频调速系统传输线特性对变频电机供电系统故障特性的影响,文中通过对含变频器和不含变频器两类供电系统分别进行Matlab/Simulink建模仿真,分析了两相短路、三相短路和电机堵转三种最为典型的过流故障,通过对比过流故障下的时域波形及技术指标揭示了变频器引入对电流波形和故障响应速度造成的影响。仿真结果表明:两相短路发生时变频器引入了新的高频谐波,堵转故障和三相短路发生时,系统不会出现新的高频谐波。短路故障发生时含变频器的系统具有更为剧烈的瞬态响应以及更高的调节时间,电流突变峰值甚至达到未装设避雷器时的3倍以上。研究填补了传输线特性对变频电机供电系统故障特性影响的研究空白,对于提升供电系统整体安全性和故障监测系统的可靠性具有重要理论参考价值。The influence of the characteristics of transmission line of the variable frequency speed regulation system on faults of the variable frequency motor power supply systems is studied.The paper analyzes the three most typical over current faults of two phase short circuit,three phase short circuit and motor locked rotor by Matlab/Simulink modeling and the simulation of the power supply system with and without frequency converter.By comparing the time domain waveforms and technical indicators under overcurrent faults,the influence of inverter introduction on current waveforms and fault response speed is revealed.The simulation results show that the inverter introduces new high frequency harmonics when the two phase short circuit occurs,while new high frequency harmonics will not happen when the locked rotor fault and three phase short circuit occur.At the same time,when the short circuit fault occurs,the system with inverter has more intense transient response and even more adjustment time,and the peak value of current sudden change even reaches more than 3 times of that with no lightning arrester.This study has supplied a gap in the research on the influence of the characteristics of the transmission line on the faults of variable frequency motor power supply systems,and provided theoretical reference for improving the overall safety of power supply systems and the reliability of fault monitoring systems.
分 类 号:TM77[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.132.213.245