保温复合铁尾矿混凝土剪力墙结构体系抗震性能试验研究  被引量:1

Experimental study on seismic performance of shear wall structure system of thermal insulation composite iron tailings concrete

在线阅读下载全文

作  者:杨恩友 莘明佳 白润山 段君胜 郭俊岩 卜娜蕊 YANG Enyou;XIN Mingjia;BAI Runshan;DUAN Junsheng;GUO Junyan;BU Narui(College of Civil Engineering,Hebei University of Architecture,Zhangjiakou 075000,China;Hebei Provincial Key Laboratory of Civil Engineering Diagnosis,Reconstruction and Disaster Relief,Zhangjiakou 075000,China;Hohhot Existing Housing Safety Appraisal and Testing Co.,Ltd.,Hohhot 010050,China)

机构地区:[1]河北建筑工程学院土木工程学院,张家口075000 [2]河北省土木工程诊断、改造与抗灾重点实验室,张家口075000 [3]呼和浩特市既有房屋安全鉴定检测有限公司,呼和浩特010050

出  处:《建筑结构》2023年第8期100-104,共5页Building Structure

基  金:张家口市科技冬奥专题项目(20110015D)。

摘  要:通过3块保温复合铁尾矿混凝土剪力墙的设计和互相对比试验,得出其荷载-应变曲线、荷载-位移滞回曲线和荷载-位移骨架曲线以及延性系数等结果,判断该新型保温复合剪力墙体系的抗震性能与可行性。结果表明:该铁尾矿混凝土制成的剪力墙比普通混凝土剪力墙的脆性大,抗震性能较弱,而剪力墙的钢筋布置和模板设计均满足条件。同时,针对此复合剪力墙体系的设计与试验,以期为铁尾矿混凝土和该新型复合剪力墙体系的应用和推广提供一定的参考数据和价值。Through the design and comparative test of three thermal insulation composite iron tailings concrete shear walls,the load-strain curve,load-displacement hysteretic curve,load-displacement skeleton curve and ductility coefficient were obtained,and the seismic performance and feasibility of the new thermal insulation composite shear wall system were judged.The results show that the shear wall made of iron tailings concrete is more brittle than ordinary concrete shear wall,and its seismic performance is weaker,while the reinforcement arrangement and formwork design of the shear wall meet the conditions.At the same time,aiming at the design and test of this composite shear wall system,in order to provide some reference data and value for the application and popularization of iron tailings concrete and this new composite shear wall system.

关 键 词:铁尾矿混凝土 抗震性能 新型保温复合剪力墙 钢筋布置 

分 类 号:TU377[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象