低压台区三相负荷不平衡治理方案  被引量:1

Three-Phase Load Imbalance Control Scheme in Low-Voltage Platform Area

在线阅读下载全文

作  者:蒋寅俊 JIANG Yinjun(Nanjing Daqo Automation Technology Co.,Ltd.,Nanjing 211100,China)

机构地区:[1]南京大全自动化科技有限公司,江苏南京211100

出  处:《通信电源技术》2023年第4期70-73,共4页Telecom Power Technology

摘  要:基于融合终端边缘算力推算出最佳三相不平衡调节方案,通过工单将该方案下达到运维班组执行调相,从而一次性完成调相工作。该方案能够使台区负载达到三相最优平衡点,解决了低压台区三相负荷不平衡问题,实现了降损节能,并提高了变压器出力,提高供电可靠性,延长了台区设备使用寿命。The optimal three-phase imbalance adjustment scheme is calculated based on the edge calculation force of the fusion terminal,and the phase adjustment is carried out by the operation and maintenance team under this scheme through the work order,so that the phase adjustment work is completed at one time.This scheme can make the load in the substation reach the three-phase optimal balance point,solve the problem of unbalanced three-phase load in the low-voltage substation,realize loss reduction and energy saving,improve the output of transformer,improve the reliability of power supply and prolong the service life of equipment in the substation.

关 键 词:三相负荷不平衡 融合终端 拓扑 调相 边缘算力 

分 类 号:TM714.3[电气工程—电力系统及自动化]

 