作 者:胡叶立 苏衡 吕万良 Hu Yeli;Su Heng;Lv Wanliang(Suichang County Environmental Monitoring Station,Suichang 323300,China;Jena Analytical Instruments(Shanghai)Co.,Ltd.,Shanghai 200000,China)
机构地区:[1]遂昌县环境保护监测站,遂昌323300 [2]耶拿分析仪器(上海)有限公司,上海200000
出 处:《分析仪器》2023年第2期79-83,共5页Analytical Instrumentation
摘 要:建立了一种测定废水中六价铬的方法。该法以聚合氯化铝为絮凝剂,调节样品pH7.5~8.5范围,絮凝沉淀分离三价铬后取上清液消解,用ICP-AES测定六价铬。实验结果表明,该法标准曲线的相关系数达到0.999以上,检出限达到0.005mg·L^(-1),RSD为1.4%~3.2%,加标回收率93.0%~102%。该法不受样品浊度和色度影响,适用于废水中六价铬的测定。This method used polyaluminum chloride as a flocculant,the pH value of the sample was adjusted to the range of 7.5-8.5.After flocculating and separating trivalent chromium,the supernatant solution was taken to digest,and the hexavalent chromium was determined by ICP-AES.Results showed that the correlation coefficient of the standard curve was above 0.999,the detection limit was 0.005mg·L^(-1),the RSD was 1.4%-3.2%,the recovery was 93.0%-102%.The method is not affected by the turbidity and chromaticity of samples,and is suitable for the determination of hexavalent chromium in wastewater.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.170