检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:白天 魏华彤 刘岩 郭林 BAI Tian;WEI Hua-tong;LIU Yan;GUO Lin(Beijing Aerospace Institute for Metrology and Measurement Technology,Beijing 100076,China;China Nuclear Power Engineering Company Limited,Beijing 100840,China;Am Incorporation for Metrology and Testing Technology Services,Suzhou 215133,China)
机构地区:[1]北京航天计量测试技术研究所,北京100076 [2]中国核电工程有限公司,北京100840 [3]阿米检测技术有限公司,苏州215133
出 处:《自动化与仪表》2023年第4期112-116,120,共6页Automation & Instrumentation
摘 要:在国内尚无高温高压标准水流量检定装置的情况下,为了保证超声波流量计在核电站主给水流量测量误差在0.3%以内,该文基于有限元分析与高温高压静态实验相结合的方法对高温高压引入的表体结构参数变形量及产生的流量测量误差进行分析。研究结果表明,设计的高温高压静态实验装置具有较高的变形量测量精度和测量稳定性。在无高温高压水流量标准装置的情况下,对提高超声波流量计在高温高压状态的测量精度具有积极作用;温度是影响表体结构参数变形的主要因素,压力影响可以忽略。表体结构参数变形量与温度之间呈线性关系,随温度的升高而增大;在P=7.8 MPa,T=226℃工况下,超声波流量计结构参数变形量引入的误差为0.64%,无法满足核电站主给水流量测量误差为0.3%的要求。In the absence of a high temperature and high pressure standard water flow verification device in China,in order to ensure that the measurement error of the ultrasonic flowmeter in the main feedwater flow of the nuclear power plant is within 0.3%,this paper analyzes the deformation of the meter body structure parameters introduced by high temperature and high pressure and the resulting flow measurement error based on the combination of finite element analysis and high temperature and high pressure static experiment.The research results show that the high temperature and high pressure static experimental device designed has high deformation measurement accuracy and measurement stability,which would play a positive role in improving the measurement accuracy of ultrasonic flowmeter in the absence of high temperature and high pressure water flow standard device.Temperature is the main factor affecting the deformation of the structural parameters of the meter body,and the influence of pressure can be ignored.There is a linear relationship between the deformation of the structure parameters of the meter body and the temperature,which increases with the increase of temperature.Under the working conditions of P=7.8 MPa,T=226℃,the error introduced by the deformation of the structural parameters of the ultrasonic flowmeter is 0.64%,which cannot meet the requirement that the main feedwater flow measurement error of the nuclear power plant is less than 0.3%.
关 键 词:超声波流量计 多声道 有限元分析 高精度 高温高压
分 类 号:TB937[一般工业技术—计量学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249