检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王晴 刘增[1] 韩鹏程 张宏伟 刘进军[1] Wang Qing;Liu Zeng;Han Pengcheng;Zhang Hongwei;Liu Jinjun(School of Electrical Engineering Xi’an Jiaotong University,Xi’an 710049 China)
出 处:《电工技术学报》2023年第8期2148-2161,共14页Transactions of China Electrotechnical Society
基 金:国家重点研发计划资助项目(2018YFB1503101)。
摘 要:针对直流微电网下垂控制变流器并联系统中变流器间内部参数差异引发的并联稳定性问题,该文采用基于变流器输出阻抗的频域方法进行研究。首先,该文建立单台下垂控制Buck变流器的输出阻抗模型并分析其特征。然后,依据该输出阻抗特征,基于变流器输出阻抗的稳定性分析方法揭示下垂控制变流器并联系统的振荡机理。在此基础上,对变流器输出阻抗进一步简化,结合并联系统振荡机理提出并联系统关键参数的稳定边界。最后,搭建下垂控制Buck变流器并联系统实验平台,通过实验验证了所提振荡机理及稳定边界的正确性。DC microgrids are of great significance for fully using renewable energy and actively responding to the carbon peaking and carbon neutrality goals.In DC microgrids,power electronics converters are usually connected to the electrical power generation units and the DC bus.These converters interact with each other through parallel connections,which increases the instability risk of the system.However,existing research regarding the system stability of DC microgrids only focuses on the influence of the interaction between the source subsystem and the load subsystem.It does not consider the difference among parallel converters in the source subsystem and thus ignores the influence of the difference among the source converters on the system stability.The difference among the source converters will cause the difference in their output impedances,which will introduce the system oscillation.Therefore,this paper focuses on the influence of the interaction among the Buck converters on the system stability,analyzes the oscillation mechanism of the parallel converters,and proposes a solution for the stability boundary.Firstly,the small-signal model of the output impedance of the single Buck converter under droop control is established in this paper,and the accuracy of the output impedance is verified by the frequency sweep in SABER.Secondly,the controller,main circuit,and parasitic parameters are analyzed to the output impedance model established,revealing the oscillation mechanism of the droop-controlled Buck converters in parallel.Thirdly,through qualitative analysis,the output impedance is further simplified.Fourthly,the stability boundary regarding the key parameters of the parallel converters is calculated by combining the oscillation mechanism revealed and the stability criterion.Finally,the experimental platform of parallel Buck converters is built to verify the correctness and effectiveness of the theoretical analysis.The experimental results of the parallel converters show that when the proportional coefficient kpi2
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.190.154.24