检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李成鹏 贺立群[1] 高明阳 林静 喻荣辉[3] 刘念[2] LI Chengpeng;HE Liqun;GAO Mingyang;LIN Jing;YU Ronghui;LIU Nian(Department of Cardiology,Wuhan No.1 Hospital,Wuhan,430022,China;Department of Cardiology,Beijing Anzhen Hospital,Capital Medical University,National Clinical Research Center for Cardiovascular Diseases;Department of Cardiology,Anhui Hospital,Beijing Anzhen Hospital,Capital Medical University)
机构地区:[1]武汉市第一医院心血管内科,武汉430022 [2]国家心血管病临床医学研究中心首都医科大学附属北京安贞医院心血管内科 [3]首都医科大学附属北京安贞医院安徽医院心血管内科
出 处:《临床心血管病杂志》2023年第3期192-196,共5页Journal of Clinical Cardiology
基 金:国家自然科学基金项目(No:82170318)。
摘 要:目的:评估三维心腔内超声(ICE)结合全三维(T3D)指引下零射线穿刺房间隔的安全性及可行性。方法:应用标测导管及消融导管构建右房、上下腔静脉及冠状窦模型,应用ICE构建左房结构。右前斜45°(RAO45°)结合左前斜135°(LAO135°)选取冠状窦口与右肺静脉开口或者右房后缘之间中点为房间隔穿刺点,在ICE结合T3D指导下进行房间隔穿刺。观察此方法房间隔穿刺成功率及并发症情况。结果:45例患者应用此方法进行房间隔穿刺,其中43例患者第1针穿刺成功(95.6%),2例患者穿刺第2针成功。平均房间隔穿刺时间(4.16±2.41)min。所有患者均无房间隔穿刺相关并发症出现。结论:应用ICE结合T3D的方法零射线穿刺房间隔安全有效,并可获得较为理想的房间隔穿刺部位。Objective: To evaluate the safety and feasibility of zero fluoroscopic transseptal puncture(TSP) under the guidance of total 3-dimension(T3D) combined with intracardiac echocardiography. Methods: The mapping catheter or the ablation catheter was employed to perform anatomical reconstruction of the right atrium, coronary sinus, and superior and inferior vena cava, while the structure of the left atrium was created by the intracardiac echocardiography(ICE). Under the position of RAO 45° and LAO 135°, the site of transseptal puncture was defined as the midpoint of the line between the coronary sinus ostium(CSo) and the ostium of the right pulmonary vein, or the line between the CSo and the posterior border of the right atrium. TSP was performed under the dual guidance of ICE and T3D, and the success rate and complications of this method were evaluated. Results: Forty-five patients underwent TSP using this method, of whom 43 patients(95.6%) succeeded with the first attempt, and 2 patients succeeded at the repeated attempt, with a mean TSP duration of 4.16±2.41 minutes. No TSP-related complications happened in these patients. Conclusion: Zero fluoroscopic TSP under the guidance of ICE and T3D is a safe and effective method, which can facilitate the selection of the ideal TSP site.
分 类 号:R541.7[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.90