摘  要:某厂300MW燃煤机组连续两个内检周期均发现存在水冷壁高温腐蚀问题,就水冷壁高温腐蚀产生的原因进行分析探讨,对高温腐蚀形态的特征、高温腐蚀分布的区域、高温腐蚀严重程度分布进行了具体描述。从运行角度切入,对于煤粉被吹到侧墙上的原因进行分析,从腐蚀机理方面对高温腐蚀进行了具体说明,最后提出针对该锅炉如何解决水冷壁高温腐蚀问题提出合理化建议。High temperature Corrosion of water wall was found in two successive internal inspection cycles of a 300MW coal-fired unit in a plant, the characteristics of high temperature corrosion morphology, the region of high temperature corrosion distribution and the distribution of high temperature corrosion severity were described in detail. From the point of view of operation, this paper analyzes the cause of coal powder blown to side wall, explains the high temperature corrosion from the corrosion mechanism, and finally puts forward some reasonable suggestions on how to solve the high temperature corrosion problem of the boiler.

关 键 词:煤粉锅炉 水冷壁 高温腐蚀 腐蚀机理 

分 类 号:TK227[动力工程及工程热物理—动力机械及工程]

 