检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:庄海洋[1] 李晟 王伟 陈国兴[1] ZHUANG Hai-yang;LI Sheng;WANG Wei;CHEN Guo-xing(Institute of Geotechnical Engineering,Nanjing Tech University,Nanjing 210009,China)
机构地区:[1]南京工业大学岩土工程研究所,江苏南京210009
出 处:《振动工程学报》2023年第2期379-388,共10页Journal of Vibration Engineering
基 金:国家自然科学基金面上项目(51778290,51978333);江苏省研究生科研与实践创新计划项目(SJCX21_0533)。
摘 要:针对地铁地下车站结构中柱、中板等抗震薄弱构件,分别研究了车站结构在传统完全约束结构形式下,在上下层中柱顶部设置弹性滑移支座时,以及本文提出的在中板边缘及底层中柱设置隔震支座时的地震反应特性,建立了土-地下结构非线性静动力耦合相互作用的二维有限元分析模型,对比分析了采用不同隔震形式对车站主体结构静动力反应特性的影响规律。结果表明:与传统车站结构相比,在中柱顶部设置弹性滑移支座能有效降低车站中柱处的地震损伤,具有更好的抗震性能。采用本文提出的中板边缘及底层中柱设置隔震支座,可以在减小中柱所受地震损伤的同时,有效地保证结构中板在强地震中不受严重损伤,从而提高车站的整体抗震性能。In view of the weak seismic components of subway underground station structure,the seismic response characteristics of the traditional station structure,the station structure with the elastic sliding bearing setting at the top of the middle columns on the top and ground floor,and the proposed station structure with the elastic sliding bearing setting at the edge of the middle plate and the middle columns on the ground floor are studied.A 2D global time-domain finite element analysis model is built for the nonlinear statically and dynamically coupled soil-main structure interaction.The influence rules of the interlayer displacement,angle,seismic damage and dynamic force response of the main structure of the station are compared and analyzed when different isolating systems are adopted.The results show that,compared with the traditional station structure,the station structure with the elastic sliding bearing setting at the top of the middle columns suffers less damage in earthquake and has better seismic performance.The station structure with the elastic sliding bearing setting at the edge of the middle plate and the middle columns on the ground floor proposed in this paper can ensure that the middle columns of the station structure are not severely damaged and can be replaced quickly after the earthquake,which can improve the overall seismic performance of the subway station structure and the rapid recovery ability of the structural function after the earthquake.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.116.239.148