某电厂锅炉后水冷壁悬吊管穿顶棚断裂事例分析  

Analysis on the fracture of the suspension pipe of the rear water wall of a power plant through the ceiling

在线阅读下载全文

作  者:郝彦勤 段宝玉 HAO Yanqin;DUAN Baoyu(Harbin Boiler Company Limited,Harbin 150046,China)

机构地区:[1]哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046

出  处:《锅炉制造》2023年第3期14-15,共2页Boiler Manufacturing

摘  要:在部分类型锅炉中,锅炉悬吊管在穿顶棚位置需与顶棚密封焊接,多数悬吊管在此位置设计有套管,安装时套管与顶棚焊接;同时存在部分悬吊管直接与顶棚密封焊接,此位置易出现工地焊接问题导致的炉管泄漏。In some types of boilers,the boiler suspension pipe needs to be sealed welded with the ceiling at the position where it passes through the ceiling.Most suspension pipes are designed with sleeves at this position,and the sleeves are welded with the ceiling during installation;At the same time,some suspension pipes are directly sealed welded with the ceiling,which is prone to furnace pipe leakage caused by site welding problems.

关 键 词:悬吊管 密封 焊接 

分 类 号:TK229[动力工程及工程热物理—动力机械及工程]

 