燃油锅炉高温再热器支撑板减薄原因分析  

Cause Analysis for High Temperature Reheater Support Plate Thinning of the Oil Fired Boiler

在线阅读下载全文

作  者:梁宝琦 李万超 LIANG Baoqi;LI Wanchao(State Key Laboratory of Efficient and Clean Coal-fired Utility Boilers(Harbin Boiler Company Limited),Harbin l50046,China)

机构地区:[1]高效清洁燃煤电站锅炉国家重点实验室(哈尔滨锅炉厂有限责任公司),黑龙江哈尔滨150046

出  处:《锅炉制造》2023年第3期35-38,共4页Boiler Manufacturing

摘  要:本文对某电厂1号锅炉高温再热器防震支撑板进行了宏观检查、化学成分分析、力学性能检测、金相组织分析、SEM/EDS分析。试验结果和综合分析表明,支撑板受到了渗碳腐蚀和硫腐蚀作用,随着腐蚀进行支撑板厚度不断减薄。In this paper,macroscopical examination,chemical composition analysis,mechanical property test,metallographic structure analysis,SEM/EDS analysis were carried out on the high temperature reheater support plate of No.1 Boiler in a power plant.The test results and comprehensive analysis showed that the support plate was subjected to carburizing corrosion and sulfur corrosion,and the thickness of the support plate is continuously thinned with corrosion.

关 键 词:支撑板 减薄 渗碳腐蚀 硫腐蚀 

分 类 号:TK229.7[动力工程及工程热物理—动力机械及工程]

 