直埋供热管道新型三通加强结构应力分析  被引量:2

Stress analysis of new tee reinforced structure for directly buried heating pipelines

在线阅读下载全文

作  者:王云翼 雷勇刚[1] 钱亨 王飞[1] 梁鹂 Wang Yunyi;Lei Yonggang;Qian Heng;Wang Fei;Liang Li(Taiyuan University of Technology,Taiyuan;Taiyuan Thermal Design Co.,Ltd.,Taiyuan)

机构地区:[1]太原理工大学,太原030024 [2]太原热力设计有限公司,太原

出  处:《暖通空调》2023年第5期162-168,共7页Heating Ventilating & Air Conditioning

基  金:住房和城乡建设部科学技术计划项目(编号:2016-K4-079)。

摘  要:针对直埋供热管道压制三通处应力过大的问题,提出了一种新型三通加强结构,旨在从根本上降低压制三通相贯处的应力,提高管道敷设安全性。通过有限元数值模拟,对比分析了新型三通加强结构与普通压制三通的应力最大值与应力分布;系统研究了肋片宽度、肋片高度、外套管厚度、肋片角度等加强模型结构参数对压制三通应力最大值的影响。结果表明:新型三通加强结构能够有效减小压制三通的应力最大值,且主管管径和支主管管径比越小,应力最大值的下降效果越明显;随肋片宽度、肋片高度和外套管壁厚的增大,新型三通加强结构应力最大值减小。Aiming at the problem of excessive stress at the stamped tee of the direct-buried heating pipeline,a new tee reinforced structure is proposed,which aims to fundamentally reduce the stress at the intersection of the tee and improve the safety of pipeline laying.Through finite element numerical simulation,the maximum stress and stress distribution law of the new tee reinforced structure and the ordinary stamped tee structure are compared and analysed.The influences of the structural parameters of the reinforced model such as the fin width,fin height,outer casing wall thickness,fin angle,etc.on the maximum stress of the stamped tee are systematically studied.The results show that the new tee reinforced structure could effectively reduce the maximum stress of the stamped tee,and the smaller the main pipe diameter and the branch-main pipe diameter ratio,the more obvious the reduction effect of the maximum stress.In addition,as the fin width,fin height and outer casing wall thickness increase,the maximum stress of the new tee reinforced structure decreases.

关 键 词:直埋供热管道 新型三通加强结构 有限元 肋片 应力 数值模拟 

分 类 号:TU995.3[建筑科学—供热、供燃气、通风及空调工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象