ECMO氧合器血液流动数值模拟及损伤评估  被引量:1

Numerical Simulation of Blood Dynamics and Damage Risk Assessment in ECMO

在线阅读下载全文

作  者:简萌 罗先武[1,2] JIAN Meng;LUO Xianwu(Department of Energy and Power Engineering,Tsinghua University,Beijing 100084;Laboratory of Cardiovascular Biomaterials and Tissue Engineering,School of Clinical Medicine,Tsinghua University,Beijing100084)

机构地区:[1]清华大学能源与动力工程系,北京100084 [2]清华大学临床医学院心血管生物材料与组织工程实验室,北京1100084

出  处:《工程热物理学报》2023年第4期977-986,共10页Journal of Engineering Thermophysics

基  金:广州实验室应急攻关项目(No.EKPG21-15)。

摘  要:为准确获得ECMO氧合器内血液流动细节,本文以交错排布的120根中空纤维束构成的简化氧合器为对象,采用基于沉浸边界法(IB)的自编程序对二维稳态血液层流进行数值模拟。结果表明,中空纤维束区域血液运动黏度变动范围在3.37~7.04×10^(-6)m^(2)/s,模拟时需要考虑血液的流变特性。通过对比IB自编程序与商业CFD软件Fluent的计算结果可知,最大壁面切应力和压降的最大相对误差分别为3.38%和2.9%,验证了IB自编程序计算氧合器微间隙流道内血液流动的准确性。与基于多孔介质假设的一维半经验公式相比,IB自编程序能够反映沿程粘性损失和惯性损失的变化,并可依据切应力累积值、溶血指数、血细胞停留时间三个指标对氧合器血液损伤风险进行综合评估。研究结果可为ECMO的性能预测、临床运行参数调节提供科学依据。In order to precisely obtain the blood flow details in ECMO oxygenators,this research takes a simplified oxygenator model consisting of 120 staggered hollow fiber bundles as the study object.The immersed boundary(IB)method code in an open-source software,foam-extend 4.0 is used to simulate the two-dimensional steady laminar flow in ECMO.The results show that in the hollow fiber region,blood kinematic viscosity changes significantly with a range from 3.37×10^(-6)m^(2)/s to 7.04×10^(-6)m^(2)/s.Therefore,the blood rheological properties should be considered.Comparing the results obtained from the IB method and commercial CFD software Fluent,the maximum wall shear stress and pressure drop values have maximum relative discrepancies of 3.38% and 2.9%,respectively.The results validate the accuracy of the IB method in simulating hemodynamics in micro gap passage of oxygenators.Compared with the one-dimensional porous media model,the IB method is capable of reflecting the correct proportion of the viscous and inertial loss.To further predict the risk of blood damage in the oxygenator,three indicators:stress accumulation value,hemolysis index,and blood cell residence time are calculated to assess the blood damage potential.Our results can provide a scientific basis for the performance prediction and operation adjustments in the clinical practice of ECMO.

关 键 词:膜式氧合器 沉浸边界法 中空纤维束 血液损伤 

分 类 号:TP393.1[自动化与计算机技术—计算机应用技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象