检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Bin Qian Tao Yu Chen Zhang Per Heiselberg Bo Lei Li Yang
机构地区:[1]School of Mechanical Engineering,Southwest Jiaotong University,610031 Chengdu,China [2]Department of Built Environment,Aalborg University,Aalborg,9100,Denmark
出 处:《Building Simulation》2023年第4期511-526,共16页建筑模拟(英文)
基 金:The first author gratefully acknowledges the financial support from the Chinese Scholarship Council(CSC No.202007000086).
摘 要:In the simulation of building overheating risks,the use of typical meteorological years(TMY)can greatly reduce the simulation workload and accurately reflect the distribution of simulation results according to the weather conditions over a given period.However,all meteorological parameters in most current TMY methods use a uniform weighting factor which may make the simulation results against the actual simulation results of the period and negatively affect the accuracy of the evaluation results.In addition to differences in climate characteristics between climate zones,the sensitivity of different simulation results to external parameters will also be different.Therefore,a TMY method based on the Finkelstein-Schafer statistical method is proposed,which considers the climatic characteristics of different regions and the correlation with the output parameters of indoor simulation to select the typical month.The proposed method is demonstrated in the three future scenarios for the three cities in different climate zones in China.The results show that the traditional TMY method has an overestimated weight of solar radiation and wind speed and an undervalued weight of dry bulb temperature when indoor temperature-related indicators are the output target.Compared with the traditional TMY method,the TMY generated by the improved method is closer to the distribution characteristics of the long-term outdoor weather data.Furthermore,when using the improved TMY data to evaluate the overheating performance of the passive residential buildings,the difference of the results of the unmet degree hours,indoor overheating degree,and the overheating escalation factor between the long-term projected data and the TMY data can be reduced by 63%–67%compared with the traditional TMY data.
关 键 词:passive buildings OVERHEATING typical meteorological year Finkelstein-Schafer statistical method
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229