X射线荧光光谱法筛选擦拭样品中铀的方法研究  

Study on the Method of Screening Uranium in Wiping Samples by X-ray Fluorescence Spectrometry

在线阅读下载全文

作  者:赵兴红[1] 王琛[1] 赵永刚[1] Zhao Xinghong;Wang Chen;Zhao Yonggang(China Institute of Atomic Energy,Beijing 102413,China)

机构地区:[1]中国原子能科学研究院放射化学研究所,北京102413

出  处:《广东化工》2023年第8期187-190,共4页Guangdong Chemical Industry

摘  要:将X射线荧光光谱法用于擦拭样品中铀微粒的筛选。本文对其方法进行了研究,绘制了标准曲线,并对模拟擦拭样品进行了测定。实验结果表明,本仪器对于光斑范围内铀浓度大于1 ppm的样品可以准确测量,误差小于10%。仪器加装移动平台后使得擦拭布的测量简便快捷,可对其铀含量进行筛选;选用移动步幅为7.2 mm时,测量最为准确。经过对空白多次测量得到仪器检测限为0.400μg。X-ray fluorescence spectrometry was used for the analysis of uranium in wipe samples.In this paper,the method was studied,the standard curve was drawn,and the sample was determined.The experimental results show that the instrument can accurately measure the samples with uranium concentration more than 1ppm in the light spot range,and the error is less than 10%.After the mobile platform is installed on the instrument,the measurement of the wiping cloth is simple and fast,and the uranium content can be screened;When the moving stride is 7.2 mm,the measurement is the most accurate.The detection limit of the instrument is 0.400μg.

关 键 词:X射线荧光光谱 移动平台 擦拭样品 铀微粒 筛选 

分 类 号:TQ[化学工程]

 