铁路牵引供电系统接触网污秽绝缘子泄漏电流在线监测系统的设计与测试  被引量:1

Design and Test of On-line Monitoring System for Pollution Insulator Leakage Current of Overhead Contact Line in Railway Traction Power Supply System

在线阅读下载全文

作  者:孙磊 Sun Lei(CHINA RAILWAY 24TH BUREAU GROU SHANGHAI ERLECOMMUNICATION AND ELECTRIFICATION CORPORATION LIMITED,Shanghai,China)

机构地区:[1]中铁二十四局集团上海电务电化有限公司,上海

出  处:《科学技术创新》2023年第11期98-101,共4页Scientific and Technological Innovation

摘  要:本研究主要探究了绝缘子泄漏电流在线监测系统的设计方案和测试效果。分析结果表明,在温度相同的情况下,空气湿度越高,绝缘子泄露电流的波形畸变情况越明显,高次谐波的幅值波动越大,绝缘子发生污闪的概率越高。This research mainly explores the design scheme and test effect of insulator leakage current on-line monitoring system.The analysis results show that,under the condition of the same temperature,the higher the air humidity,the more obvious the waveform distortion of insulator leakage current,the greater the amplitude fluctuation of higher harmonic,the higher the probability of insulator pollution flashover.

关 键 词:铁路接触网 泄漏电流在线监测系统 电流传感器 污闪 

分 类 号:U225.43[交通运输工程—道路与铁道工程]

 