青藏高原多年冻土区露天煤矿边坡地温预测模型研究  被引量:2

Study on ground temperature prediction model of open-pit coal mine slope in permafrost area of Qinghai-Tibet Plateau

在线阅读下载全文

作  者:张宏刚 汪启龙[2,4] ZHANG Honggang;WANG Qilong(Engineering Ecological and Environmental Technology Co.,Ltd.of CCTEG,Beijing 100013,China;Xi’an Research Institute of CCTEG,Xi’an Shaanxi 710077,China;Xi’an University of Technology,Xi’an Shaanxi 710048,China;National Key Laboratory of Permafrost Engineering,Northwest Institute of Ecological Resources and Environment,Chinese Academy of Sciences,Lanzhou Gansu 730000,China)

机构地区:[1]中煤科工生态环境科技有限公司,北京100013 [2]中煤科工集团西安研究院有限公司,陕西西安710077 [3]西安理工大学,陕西西安710048 [4]中国科学院西北生态资源环境研究院冻土工程国家重点实验室,甘肃兰州730000

出  处:《中国安全生产科学技术》2023年第4期56-63,共8页Journal of Safety Science and Technology

基  金:国家自然科学基金项目(41374110);中国科学院冻土工程国家重点实验室开放基金项目(SKLFSE201311);中煤科工集团西安研究院有限公司科技创新基金项目(2012XAYCX020,2014QN015);中国煤炭科工集团有限公司科技创新创业资金专项项目(2019-ZD004);中煤科工生态环境科技有限公司科技创新基金项目(0206KGST0022)。

摘  要:为预测青藏高原多年冻土区露天煤矿边坡地温变化,揭示多年冻土分布规律,指导寒区露天矿安全生产,以木里煤田聚乎更矿区露天矿边坡2011—2014年地温监测数据为基础,通过数据的统计与拟合,依据传热学理论建立研究区多年冻土地温预测模型,并利用邻区露天矿冻土地温监测结果与数值模拟对预测模型精度进行验证。研究结果表明:木里煤田聚乎更矿区露天矿边坡季节活动层厚度普遍在5.75~6.59 m,多年冻土下限在63.85~64.35 m,地温年变化深度在11.65~12.25 m;采矿揭露后,边坡表层原生多年冻土演化为3.85~5.65 m季节活动层;坡面季节活动层厚度较原生季节活动层厚度略薄,随着冻融循环周期的递增,其厚度逐渐接近原生厚度;冻土地温变化曲线与简谐波波形线接近。本文所提出的冻土地温预测模型可用于预测青藏高原多年冻土区边坡地温变化,研究结果可为寒区露天矿边坡稳定性研究提供技术支撑。In order to predict the ground temperature change of open-pit coal mine slope in the permafrost area of Qinghai-Tibet Plateau,reveal the permafrost distribution rule,and guide the work safety of open-pit mine in cold region,based on the ground temperature monitoring data of open-pit mine slope in Juhugeng mining area of Muli coal field from 2011 to 2014,a prediction model of permafrost ground temperature in the study area was established according to the heat transfer theory through the data statistics and fitting,and the accuracy of prediction model was verified by the monitoring results and numerical simulation of permafrost ground temperature in the adjacent open-pit mine.The results showed that the thickness of seasonal active layer of open-pit mine slope in Juhugeng mining area of Muli coal field was generally 5.75~6.59 m,the lower limit of permafrost was 63.85~64.35 m,and the annual change depth of ground temperature was 11.65~12.25 m.After the mining exposure,the primary permafrost on the slope surface evolved into a seasonal active layer of 3.85~5.65 m.The thickness of seasonal active layer on the slope was slightly thinner than that of the primary seasonal active layer,and with the increase of the freeze-thaw cycle,its thickness gradually approached the primary thickness.The change curve of permafrost ground temperature was close to the simple harmonic waveform line.The proposed prediction model of permafrost ground temperature can be used to predict the ground temperature change of slope in the permafrost area of Tibetan Plateau,and the results can provide technical support for the research on the stability of open-pit mine slope in cold region.

关 键 词:青藏高原 多年冻土 露天煤矿 地温 预测模型 

分 类 号:TD164[矿业工程—矿山地质测量] X936[环境科学与工程—安全科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象