检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Mohammad Irfan Iqbal Shuo Shi Gokula Manikandan Senthil Kumar Jinlian Hu
机构地区:[1]Institute of Textiles and Clothing,The Hong Kong Polytechnic University,Hong Kong 999077,China [2]Department of Biomedical Engineering,City University of Hong Kong,Hong Kong 999077,China [3]Department of Building Environment and Energy Engineering,The Hong Kong Polytechnic University,Hong Kong 999077,China
出 处:《Nano Research》2023年第2期2563-2571,共9页纳米研究(英文版)
基 金:the Contract Research(Development of Breathable Fabrics with Nano-Electrospun Membrane,CityU ref.:9231419);the National Natural Science Foundation of China(Study of Multi-Responsive Shape Memory Polyurethane Nanocomposites Inspired by Natural Fibers,Grant No.51673162);Start-up Grant of CityU(Laboratory of Wearable Materials for Healthcare,Grant No.9380116).
摘 要:Functional textiles that promote daily comfort and productivity must efficiently release body sweats and transmit radiative heat through sweat evaporation and mid-infrared radiation(MIR)(8–13μm).However,most of the traditional clothing cannot provide simultaneous sweat evaporation and mid-infrared radiation transmission efficiently,leading to a poor design of personal cooling wearables.Herein,an evaporative/radiative integrated functional fibrous electrospun membrane is meticulously designed and controllably fabricated via facile electrospinning technology for personal cooling management.The developed membrane can be applied as a smart wearable with distinct personal thermal management applications.The promising temperature and humidity responsive vapor transmission of the membrane grants 1.2 times of evaporative cooling than that of traditional cotton.Besides,based on its high mid-infrared radiation transmission(53%)property in the range of 8–13μm,the as-spun membrane provides extra cooling of 1.5°C than that of cotton.Moreover,the building energy saving performances demonstrated that 47.1%annual building cooling can be achieved using the developed electrospun membrane.In general,the evaporative/radiative electrospun membrane creates a passive cooling microclimate for the human body,meeting the growing demand of wearable for personal cooling.
关 键 词:building energy cooling management ELECTROSPINNING evaporative cooling radiative cooling