摘  要:2号离心机机组投入运行2个月后经常出现离心机机组轻载、排气量下降现象,针对这一问题,对离心机机组进行了一系列的排查和改进,达到了预期效果,使离心机机组恢复了正常运行.In view of the phenomenon that the light load and exhaust volume reduction of the centrifuge unit often occur after the No.2 centrifuge unit has been put into operation for 2 months,a series of inspections and improvements have been carried out on the centrifuge unit,which have achieved the expected effect and restored the normal operation of the centrifuge unit.

关 键 词:离心机 干燥器 轻载 排气量 压降 阻力 