检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李晓涛 黄海堂 杨静远 何曲波 李卫民 郑雅文 Li Xiaotao;Huang Haitang;Yang Jingyuan;He Qubo;Li Weimin;Zheng Yawen(China Nuclear Power Engineering Co.,Ltd.,Shenzhen Guangdong 518124,China;Chongqing Material Research Institute Co.,Ltd.,Chongqing 400707,China;Nuclear and Radiation Safety Center,Ministry of Ecology and Environment,Beijing 100082,China;Shanghai Rocksensor Automation Co.,Ltd.,Shanghai 210018,China)
机构地区:[1]中广核工程有限公司,广东深圳518124 [2]重庆材料研究院有限公司,重庆400707 [3]生态环境部核与辐射安全中心,北京100082 [4]上海洛丁森工业自动化设备有限公司,上海210018
出 处:《金属热处理》2023年第4期79-84,共6页Heat Treatment of Metals
基 金:中国机械工业集团有限公司重大科技专项(SINOMAST-ZDZX-2019-03,SINOMAST-ZDZX-2018-05)。
摘 要:研究了热处理工艺对测量膜片材料3J53合金组织性能的影响。结果表明,3J53合金在920~1010℃温度区间固溶处理10 min时可获得均匀细小的晶粒组织和较低的硬度。并且,在980℃固溶温度下,合金晶粒尺寸的大小随固溶时间的增长变化不明显。进一步研究证明,3J53合金经920~1010℃×10 min固溶+670℃×5 h时效后,硬度为302~346 HV0.2,无法满足压力变送器要求。但经920℃固溶+冷轧+650~700℃×5 h时效处理后,材料的硬度显著提高。同时,当时效处理温度为670℃时,硬度达到峰值483 HV0.2,满足核级压力变送器要求。与进口产品对比发现,研制的3J53合金测量膜片样品的硬度、回差性能和原始量程温度影响性能均无显著差异,满足国产化应用要求。Effect of heat treatment process on the microstructure and properties of the diaphragm material 3J53 alloy was studied.The results show that after solution at 920-1010℃for 10 min,the 3J53 alloy can obtain uniform and fine grain structure but lower hardness.The grain size did not change obviously after solution at 980℃for different time.After solution at 920-1010℃for 10 min and aging at 670℃for 5 h,the hardness is 302-346 HV0.2,which can not meet the requirements of pressure transmitter.After solution at 920℃and cold rolling and then aging at 650-700℃for 5 h,the hardness increases significantly,which reaches a peak value of 483 HV0.2 when aging at 670℃,that can meet the requirements of nuclear grade pressure transmitter.Compared with the imported products,it is found that there is no significant difference in the hardness,return difference performance and original range temperature influence performance of the domestic 3J53 alloy diaphragm specimen,which meet the requirements of domestic application.
关 键 词:核级压力变送器 恒弹性合金 显微组织 测量膜片 性能验证
分 类 号:TG335[金属学及工艺—金属压力加工]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.147