Retrospective Analysis of External Quality Assessment Data of Humoral (Except Feces) Morphology in Guangxi from 2010 to 2022  

在线阅读下载全文

作  者:Ciying XIAO Xiaochun LIU Juan TANG Hongying ZHAO Xiangyang ZHOU Shengzhou NONG 

机构地区:[1]Guangxi Clinical Laboratory Center,People s Hospital of Guangxi Zhuang Autonomous Region,Nanning 530021,China [2]Department of Laboratory Medicine,People s Hospital of Guangxi Zhuang Autonomous Region,Nanning 530021,China

出  处:《Medicinal Plant》2023年第2期107-112,共6页药用植物:英文版

基  金:Supported by the Scientific Research Project of Guangxi Health Commission (Z2014221)。

摘  要:[Objectives] The study aims to improve the ability of inspectors to recognize humoral morphology and provide data reference for the improvement of EQA work of humoral morphology by Guangxi Clinical Laboratory Center. [Methods] A retrospective analysis was made on the EQA of humoral morphology by Guangxi Clinical Laboratory Center from 2010 to 2022, and the number of participating laboratories, the rate of return, sample types and maps of EQA of humoral morphology such as urine sediment, vaginal secretions and so on(except feces), and the reasons for the high error rate of the results of the participating laboratories were analyzed. [Results] The number of laboratories participating in the assessment of humoral morphology increased from 98 in 2010 to 371 in 2022. Except for 2011(90.98%), the rate of return was more than 94%, and the highest rate of return was up to 100%. A total of 119 pictures of EQA of humoral morphology were studied, including 101 urine sediment smears, 13 vaginal secretions smears and 5 other smears. The types of specimens were relatively comprehensive. The distribution of the maps was basically reasonable. The urinary sediment was mainly composed of crystalline salts, followed by tubes, and cells and fungi ranked third. The coverage was relatively complete. The error rate of return results from high to low were bacteria(error rate was equal to 40%), tubes and crystalline salts(error rate was close to 29%), and cells and fungi(error rate was about 14%). The main cases with high error rate of return results are as follows: the difference between different tubes was not clear, and the diversity of crystal morphology was not understood enough;the phase division of cells in the same system was wrong. [Conclusions] The analysis and summary of the reasons for the high error rate of the data and results of Guangxi's EQA of humoral morphology is helpful for laboratory physicians to improve their awareness of morphological examination and identify clearly the error type and blurred concept, and lays a

关 键 词:Humoral morphology External quality assessment Retrospective analysis 

分 类 号:R446.1[医药卫生—诊断学]

 