摘 要:以宁波市高新区某办公楼空调系统为例,分析既有建筑热泵系统在高温环境下能效低的原因。引入新型细水雾装置,对比案例建筑改造前后的运行数据,旨在提高热泵机组的能效。安装新型细水雾装置能够提高既有建筑上的空调热泵机组的能效,实现建筑物空调系统高效运转。Taking the air conditioning system of an office building in Ningbo High-tech Zone as an example,the reasons for the low energy efficiency of the heat pump system of the existing building in the high temperature environment are analyzed.A new water mist device was introduced to compare the operation data before and after the renovation of the case building,aiming to improve the energy efficiency of the heat pump unit.The installation of a new water mist device can improve the energy efficiency of the air conditioning heat pump unit on the existing building and realize the efficient operation of the building air conditioning system.