利用热平衡计算干熄焦的烧损率  被引量:2

Using heat balance to calculate the burning loss rate of CDQ

在线阅读下载全文

作  者:袁本雄 邵胜平 左夏青 汪银 徐正 Yuan Benxiong;Shao Shengping;Zuo Xiaqing;Wang Yin;Xu Zheng(Tongling Pacific Specal Materials Co.,Ltd.;Liaoning Enthalpy Increase Engineering and Research Co.,Ltd.)

机构地区:[1]铜陵泰富特种材料有限公司 [2]辽宁盛焓工程技术有限公司

出  处:《冶金能源》2023年第3期44-46,57,共4页Energy For Metallurgical Industry

摘  要:对干熄焦系统计算范围进行合理划分后,可以求出各部分的热量,从而利用热平衡求得干熄焦的烧损率。利用热平衡求干熄焦烧损率,可以实时计算用于监控干熄焦操作,还可以求出干熄焦系统的理论蒸发量,为锅炉选型提供一定依据。After the calculation range is divided reasonably,the heat of each part of the CDQ system can be obtained,and the burn loss rate of CDQ can be obtained by using the heat balance.Using the heat balance to find the CDQ burning loss rate,real-time calculation can be performed to monitor the CDQ operation,and the theoretical evaporation capacity of the CDQ system can also be obtained to provide a certain basis for boiler selection.

关 键 词:干熄焦 烧损率 实时计算 热平衡 

分 类 号:TQ520.6[化学工程—煤化学工程]

 