摘 要:对目前动车组辅助变流器电流型和电压型两种接地检测方式进行对比研究,对两种接地检测方式的工作原理进行说明,推导了两种接地检测方法的计算公式,并阐述了采用两种接地检测方式判断动车组辅助变流器是否发生单相接地故障的保护逻辑,最后给出了两种接地检测方式的对比研究结果。The current and voltage detection methods of the auxiliary converter of EMUs are compared and studied,the working principle of the two grounding detection is explained,and the calculation formula of the two grounding detection methods is derived.The protection logic of using two grounding detection methods to determine whether a single-phase ground fault occurs in the auxiliary converter of the EMU is expounded.Finally,the comparative results of the two grounding detection methods are given.