检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Esther Lee Jane Y.Tong Luke J.Pasick Daniel A.Benito Arjun Joshi Punam G.Thakkar Joseph F.Goodman
机构地区:[1]Division of Otolaryngology-Head and Neck Surgery,George Washington University School of Medicine& Health Sciences,Washington,DC,USA [2]Western University of Health Sciences,Pomona,CA,USA [3]Department of Otolaryngology-Head and Neck Surgery,Drexel University College of Medicine,Philadelphia,PA,USA [4]Department of Otolaryngology-Head and Neck Surgery,University of Miami Miller School of Medicine,Miami,FL,USA
出 处:《World Journal of Otorhinolaryngology-Head and Neck Surgery》2023年第1期35-44,共10页世界耳鼻咽喉头颈外科杂志(英文)
摘 要:Objective:Harmonic Focus(Ethicon,Johnson and Johnson,Cincinnati,OH,USA),LigaSure Small Jaw(Medtronic,Covidien Products,Minneapolis,MN,USA),and Thunderbeat Open Fine Jaw(Olympus,Japan)are electrosurgical instruments used widely in head and neck surgery.The study aims to compare device malfunctions,adverse events to patients,operative injuries,and interventions related to Harmonic,LigaSure,and Thunderbeat use during thyroidectomy.Methods:The US Food and Drug Administration's Manufacture and User Facility Device Experience(MAUDE)database was queried for adverse events associated with Harmonic,LigaSure,and Thunderbeat from January 2005 to August 2020.Data were extracted from reports pertaining to thyroidectomy.Results:Of the 620 adverse events extracted,394(63.5%)involved Harmonic,134(21.6%)LigaSure,and 92(14.8%)Thunderbeat.The reported device malfunctions most frequently associated with Harmonic was damage to the blade(110(27.9%)),LigaSure was inappropriate function(47(43.1%)),Thunderbeat was damage to the tissue or Teflon pad(27(30.7%)),respectively.Burn injury and incomplete hemostasis were the most commonly reported adverse events.The operative injury reported most frequently when using Harmonic and LigaSure was burn injury.No operator injuries were reported with Thunderbeat use.Conclusion:The most frequently reported device malfunctions were damage to the blade,inappropriate function,and damage to the tissue or Teflon pad.The most frequently reported adverse events to patients was a burn injury and incomplete hemostasis.Interventions aimed at improving physician education may help reduce adverse events attributed to improper use.
关 键 词:Adverse events HARMONIC LIGASURE Manufacture and User Facility Device Experience Patient safety Quality Thunderbeat THYROIDECTOMY
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.124