检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨帅 刘洪吉 吴二波 李刚涛 吕潇 戴小野 陶帅 YANG Shuai;LIU Hongji;WU Erbo;LI Gangtao;LYU Xiao;DAI Xiaoye;TAO Shuai(Super-high-voltage Company of State Grid Hebei Electric Power Co.,Ltd.,Shijiazhuang 050000)
机构地区:[1]国网河北省电力有限公司超高压分公司,河北石家庄050000
出 处:《电力安全技术》2023年第5期63-66,共4页Electric Safety Technology
摘 要:针对架空地线绝缘装置缺陷造成线路安全稳定性下降的问题,通过分析绝缘装置设计与安装过程中可能存在的缺陷,归纳出影响绝缘装置性能的因素有施工安装、自然因素、出厂设计、线路负荷、分段绝缘等,并提出治理与防范措施,以改善输电系统的暂态稳定性,提升运行安全性。As for the defect in the insulation devices of overhead grounding wires which brings about the performance degradation of safety and stability of lines.By analysis on the defects that might exist in the design and installation of such insulation devices,the factors influencing the performance of insulation devices are summarized such as the construction and installation,natural factors,factory design,line load and sectional insulation,etc.,based on which the specific settlement and preventive measures are put forward so as to improve the transient stability and operating safety of transmission lines.
分 类 号:TM910.2[电气工程—电力电子与电力传动]