作 者:侯雨潇 毛宁波 曹耕毓 王丽 张煜[2] 赵宇[1] HOU Yuxiao;MAO Ningbo;CAO Gengyu;WANG Li;ZHANG Yu;ZHAO Yu(Department of Orthopaedics,Peking Union Medical College Hospital,Chinese Academy of Medical Sciences&Peking Union Medical College,Beijing,100730;School of Mechanical Engineering,Xi'an Jiaotong University,Xi'an,710049;Beijing Fule Science&Technology Development Co.Ltd.,Beijing,101204)
机构地区:[1]中国医学科学院北京协和医学院北京协和医院骨科,北京市100730 [2]西安交通大学机械工程学院,西安市710049 [3]北京市富乐科技开发有限公司,北京市101204
出 处:《中国医疗器械杂志》2023年第3期252-257,共6页Chinese Journal of Medical Instrumentation
基 金:北京市科学技术委员会支持(Z191100004419005)。
摘 要:基于时频联合分析法(JASA),开展基于表面肌电信号的脊柱手术器械上肢操作肌肉疲劳评估研究,完成脊柱手术器械优化前后操作舒适性的对比测评。共招募17名受试者分别采集其肱桡肌和肱二头肌的表面肌电信号,选取5种优化前后的手术器械进行数据对比,基于RMS和MF特征值计算相同任务下各组器械的操作疲劳时间占比。结果表明完成相同操作任务时,优化前手术器械的操作疲劳时间显著高于优化后器械(P<0.05);操作同一器械,肱桡肌和肱二头肌疲劳状态无显著性差异(P>0.05),这为手术器械的人因学设计及疲劳损伤防护等提供客观数据及参考。Based on the joint analysis of EMG spectrum and amplitude method(JASA),a study on muscle fatigue assessment of spinal surgical instruments based on surface EMG signals was carried out,and a comparative evaluation of the operating comfort before and after the optimization of spinal surgical instruments was completed.A total of 17 subjects were recruited to collect the surface EMG signals of their brachioradialis and biceps.Five surgical instruments before and after optimization were selected for data comparison,and the operating fatigue time proportion of each group of instruments under the same task was calculated based on the RMS and MF eigenvalues.The results showed that when completing the same operation task,the operation fatigue time of the surgical instruments before optimization was significantly higher than that after optimization(P<0.05);there was no significant difference in the fatigue status of brachioradialis and biceps when operating the same instrument(P>0.05).These results provide objective data and reference for the ergonomic design of surgical instruments and fatigue damage protection.
关 键 词:脊柱手术器械 肌肉疲劳 表面肌电信号 时频联合分析法(JASA)
分 类 号:R318[医药卫生—生物医学工程] TH781[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.93