作 者:吴海涛 韩兴波 蒋兴良[3] 郭思华 Wu Haitao;Han Xingbo;Jiang Xingliang;Guo Sihua(State Grid Chongqing Electric Power Company Chongqing Electric Power Research Institute,Chongqing 401123 China;School of Mechatronics and Vehicle Engineering Chongqing Jiaotong University,Chongqing 400074 China;State Key Laboratory of Power Transmission Equipment&System Security and New Technology Chongqing University,Chongqing 400044 China)
机构地区:[1]国网重庆电力公司电力科学研究院,重庆750002 [2]重庆交通大学机电与车辆工程学院,重庆400074 [3]输配电装备及系统安全与新技术国家重点实验室(重庆大学),重庆400044
出 处:《电工技术学报》2023年第11期3033-3040,3051,共9页Transactions of China Electrotechnical Society
摘 要:输电线路导线覆冰危害电力输送安全,导线防冰/除冰方法一直是国内学者关注的焦点。近年来,利用扩径导线进行防冰的方法被一些学者提出。该文针对扩径导线防冰特性问题,对不同直径导线表面的水滴碰撞和冻结过程进行分析,研究了导线直径对水滴碰撞系数和覆冰速率的影响,提出扩径导线临界防冰直径D_(p)的计算方法,并对不同风速、水滴中值体积直径和不同温度条件下的D_(p)值进行了仿真计算。此外,通过不同直径铝管的自然覆冰试验对扩径导线的防冰性能进行了验证。研究结果表明:扩径导线表面的最大水滴碰撞系数随着直径的增大而减小,但水滴碰撞范围会扩大;由于导线表面的水滴捕获率和覆冰速率均随着直径的增大先增加后减小,利用扩径导线进行防冰需使其直径大于临界防冰直径D_(p),风速、水滴中值体积直径越大,环境温度越高,D_(p)值越大。Conductor icing endangers the safety of power grid.Conductor anti-icing and de-icing methods have always been the focus of domestic scholars.In recent years,the method of using expanded conductor for anti-icing has been put forward by some scholars.In order to understand the anti-icing characteristics of expanded conductor,firstly,the water droplet collision and freezing process on the conductor with different diameter are analyzed.Based on the boundary element method,considering the drag effect of airflow on water droplets,a computational model of airflow field on conductors is established,and the overall collision efficiency of water droplets on conductors is obtained by tracking the trajectory of water droplets,which represents the droplet capture ability of conductors with different diameters.Secondly,the influence of conductor diameter on water droplet collision efficiency and icing rate is studied.The simulation results show that the airflow drag force on the water droplets increases due to the increase of the conductor diameter,which reduces the ratio of the water droplet collided with the conductor due to the inertial effect.And the overall droplet collision efficiencyon conductor surface gradually decreases with the increase of the conductor diameter.However,as the maximum local droplet collision efficiency is at the stagnation point on the windward side,with the increase of conductor diameter,the maximum local droplet collision efficiency at the stagnation point gradually decreases.And the collision range is expanding,resulting in the amount of captured water droplets stopping decreasing with the increase of conductor diameter.Therefore,it is necessary to calculate the overall water droplets capturedby the conductor per unit time dM/dt to determine the droplets capturing capacity ofconductorswithdifferentdiameters.Thirdly,the definition of the critical anti-icing diameter of the expanded conductor is proposed as follows:under the same environmental conditions,when the diameter of the expanded conductor
分 类 号:TM85[电气工程—高电压与绝缘技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7