钢管约束的钢管混凝土轴压短柱长期变形性能  被引量:4

Deformation behavior of steel tube-confined concrete-filled steel tube columns under sustained axial compression

在线阅读下载全文

作  者:李艳华 张素梅 王焰 王玉银[2] LI Yanhua;ZHANG Sumei;WANG Yan;WANG Yuyin(Civil and Environmental Engineering,Harbin Institute of Technology(Shenzhen),Shenzhen 518000,Guangdong,China;School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China)

机构地区:[1]哈尔滨工业大学(深圳)土木与环境工程学院,广东深圳518000 [2]哈尔滨工业大学土木工程学院,哈尔滨150090

出  处:《哈尔滨工业大学学报》2023年第9期101-110,共10页Journal of Harbin Institute of Technology

基  金:深圳市高层次人才项目。

摘  要:为分析钢管约束的钢管混凝土柱在长期荷载作用下的变形性能,进行了16个钢管约束的钢管混凝土短柱和2个钢管混凝土短柱的长期持荷试验,持荷时间为350d。主要研究参数核心混凝土应力比为0.35.0.50和0.65,双层钢管总含钢率为5.8%、10.5%和15.0%,内层钢管与外层钢管含钢率比值为0.30、1.25和2.23。基于素混凝土的长期变形理论计算模型,通过分析施加纵向长期荷载时构件的受力机理,推导出适用于钢管约束的钢管混凝土轴压短柱长期变形的理论计算方法。试验结果表明:长期变形随核心混凝土应力比的提高而增大,随总含钢率、内层与外层钢管含钢率比值的增大而减小。理论计算曲线与试验数据曲线的对比和分析表明:长期变形随相对湿度的减小而增大,采用不同混凝土收缩徐变模型时,相对湿度的影响程度不同,其中CEB-FIP2010模型的吻合效果最好。建议采用CEB-FIP2010模型并取相对湿度为100%来计算钢管约束的钢管混凝土柱的长期变形。Long-term tests under axial compression were carried out on 16 steel tube-confined concrete-filled steel tube columns and two concrete-filled steel tube columns for 350 d to investigate the long-term deformation performance.The main research parameters were stress ratio of the core concrete(0.35,0.50,and 0.65),total steel ratio of the inner and outer steel tubes(5.8%,10.5%,and 15.0%),and the stel ratio between the inner and outer steel tubes(0.30,1.25,and 2.23).The working mechanism of the steel tube-confined concrete-flled steel tube columns under long-term axial compression was analyzed,and a theoretical calculation method for longterm deformation of steel tube-confined concrete-filled steel tube columns was established.Results show that the long-term deformation increased with the increase in the stress ratio of the core concrete,and decreased when the total steel ratio and the ratio between the inner and outer steel tubes increased.The comparison between the theoretical and test results shows that the long-term deformation increased with the decrease in relative humidity.When different concrete shrinkage and creep models were used,the influence of relative humidity varied,and the CEB-FIP 2010 model had the best performance.Therefore,the CEB-FIP 2010 model with 100%relative humidity is recommended for the calculation of steel tube-confined concrete-filled steel tube columns under long-term deformation.

关 键 词:长期荷载 钢管约束 钢管混凝土 收缩徐变 相对湿度 

分 类 号:TU398[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象