出  处:《中国组织工程研究》2024年第6期922-926,共5页Chinese Journal of Tissue Engineering Research

摘  要:背景:近年来,随着3D打印技术的发展,使得外科手术走向个性化、精准化。3D打印导板技术可实现术前规划、术中导航,使得外科手术更加精准。临床中重度僵硬性脊柱侧弯矫形术中仍面临置钉准确性不高导致螺钉松动甚至引起神经并发症的问题,现有关于3D打印导板技术指导重度僵硬性脊柱侧弯术中置钉的研究不多。目的:评价3D打印导向模板技术联合后路多次去旋转治疗重度僵硬性脊柱侧凸的临床效果。方法:回顾性分析3D打印导向模板椎弓根螺钉置入后联合施行后路多次转棒去旋转技术治疗重度脊柱侧凸6例患者的临床资料,男3例,女3例,手术时年龄15-23岁,平均(18.17±3.49)岁。分析术后2周和术后18个月时脊柱侧弯相关参数的变化,进行统计学分析。结果与结论:(1)手术时间280-540 min,平均(340.83±102.20)min,术中出血量1000-4000 mL,平均(2000.00±1073.70)mL,固定节段9-14个椎体,平均(11.83±1.72)个椎体,矫形过程中未出现螺钉松动;(2)所有患者均获得随访,术后2周全脊柱正侧位片显示冠状位主弯的cobb角、冠状面C_(7)铅垂线和S1正中线的距离、矢状面C_(7)铅垂线和S1后缘的距离、顶椎偏移、胸椎后凸角、腰椎前凸角均获得明显矫正,主弯的cobb角平均矫正率62.22%,术后18个月随访各参数较术后2周无明显变化,矫形效果满意,无感染和内固定断裂;(3)围术期切口延迟愈合1例,经过换药处理瘢痕愈合,未出现神经并发症;(4)结果表明3D打印导向模板结合后路多次转棒去旋转技术治疗重度僵硬性脊柱侧凸畸形安全有效,矫形效果满意。BACKGROUND:In recent years,with the development of 3D printing,surgical surgery has become personalized and accurate.3D printed guide template technique can realize preoperative planning and intraoperative navigation,making surgery more accurate.In clinical orthopedic surgery for moderate and severe stiff scoliosis,there is still a problem that the accuracy of screw placement is not high,resulting in screw loosening and even nerve complications.There are few studies on 3D printed guide template technique to guide screw placement in surgery for severe stiff scoliosis.OBJECTIVE:To evaluate the clinical effect of the 3D printed guide template technique combined with multiple posterior derotation in the treatment of severe rigid scoliosis.METHODS:The clinical data of six patients with severe scoliosis undergoing 3D printed guide template technique of pedicle screw combined with multiple posterior derotation were retrospectively analyzed.There were 3 males and 3 females,with a mean age of(18.17±3.49)years(range,15-23 years).The changes of parameters related to lateral bending were analyzed at postoperative 2 weeks and 18 months,and the results were obtained by statistical analysis.RESULTS AND CONCLUSION:(1)The operation time was 280-540 minutes(mean 340.83±102.20 minutes).The intraoperative blood loss was 1000-4000 mL(mean 2000.00±1073.70 mL).The fixed segments were 9-14 vertebral bodies(mean 11.83±1.72),and no screw loosening occurred during the operation.(2)All patients were followed up.At postoperative 2 weeks,the anteroposterior and lateral radiography of the whole spine showed that the cobb angle,the distance between the vertical line of C_(7) on the coronal plane and the median line of S1,the distance between the vertical line of C_(7) in the sagittal plane and the posterior edge of S1,apical vertebral translation,thoracic kyphosis,and lumbar lordosis were significantly corrected.The average correction rate of the cobb angle in the main curve was 62.22%.After 18 months of follow-up,there was no significant c

关 键 词:重度僵硬性脊柱侧凸 去旋转 3D打印导板技术 肋骨切除术 CT三维重建 

分 类 号:R459.9[医药卫生—治疗学] R318[医药卫生—临床医学] R682

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象