检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:潘承基 PAN Cheng-ji
机构地区:[1]中电(普安)发电有限责任公司,贵州普安561500
出 处:《节能》2023年第5期64-67,共4页Energy Conservation
摘 要:针对锅炉脱硝稀释风系统中灰与氨气结晶物易堵塞喷氨支路阀门和喷嘴的问题,采用经热一次风加热后的冷一次风作为稀释风源替代原空预器出口热一次风,并分析其经济性与可行性。结果显示:稀释风系统改造后,气气换热器(GGH)出口稀释风温远超过200℃并且不超过320℃,满足尿素水解产品对稀释风温度的要求;解决了喷氨格栅堵塞问题,喷氨管路喷氨均匀性得到改善,系统总氨耗量下降,经济性得到提高。Aiming at the problem that the ash and ammonia crystals in the boiler denitrification dilution air system of the boiler are easy to block the valves and nozzles of the ammonia injection branch,the cold primary air heated by the hot primary air is used as the dilution air source to replace the hot primary air at the outlet of the original air preheater,and its economy and feasibility were analyzed.The results show that after the dilution air system is reformed,the temperature of the dilution air at the outlet of the gas-gas heat exchanger(GGH)far exceeds 200℃and does not exceed 320℃,which meets the requirements of the urea hydrolyzed product for the dilution air temperature.The blockage of the ammonia injection grille is solved.The uniformity of ammonia injection in the ammonia injection pipeline is improved,the overall ammonia consumption of the system is reduced,and the economy is improved.
关 键 词:喷氨堵塞 气气换热器(GGH) 稀释风系统
分 类 号:X701[环境科学与工程—环境工程]