作 者:许延春[1] 苗葳[1,2] 宛志红 叶精灵 李磊 邢晁瑞 XU Yanchun;MIAO Wei;WAN Zhihong;YE Jingling;LI Lei;XING Chaorui(School of Energy and Mining Engineering,China University of Mining Technology(Bejing),Beijing 100083,China;Jiaozuo Coal Industry Group Co.,Ltd.,Jiaozuo 454002,China;Jiulishan Coal Mine of Jiaozuo Coal Industry Group Co.,Ltd.,Jiaozuo 454005,China)
机构地区:[1]中国矿业大学(北京)能源与矿业学院,北京100083 [2]焦作煤业(集团)有限责任公司,河南焦作454002 [3]焦作煤业(集团)有限责任公司九里山矿,河南焦作454005
出 处:《煤矿安全》2023年第5期63-71,共9页Safety in Coal Mines
摘 要:为研究华北煤田大水矿区底板注浆加固改造工作面突水机理和防治水效果,采用力学公式推导、水文地质特征分析,应用微震监测、瞬变电磁探测等成果,研究了注浆加固改造工作面底板结构稳定关键层与底板破坏渗透关键层叠加控水机理,构建了“双关键层”控水模型,提出了影响“双关键层”控水能力的2类7因素工程判据,并在焦作矿区进行工程研究。结果表明:底板浅部富水性强含水层经注浆改造后岩体强度增加40%~159%,岩体最大抗拉强度达到5.78MPa,最大抗剪强度达到38.31 MPa,底板变形量减少,从而降低底板破坏和渗透程度,能够起到底板结构稳定控水关键层的作用;破坏渗透控水关键层对裂隙发展起到充填与抑制作用,能够防止深部含水层向上充水;破坏渗透控水关键层有效阻水厚度不足与断层活化是造成底板“双关键层”控水失效的主要原因。In order to study the water inrushing mechanism of floor reinforcement working face and the grouting effect in water abundant mining area of North China Coalfield,by means of mechanical formula derivation,hydro-geological characteristics analysis,micro-seismic monitoring and transient electromagnetic detection results,the superimposed water control mechanism of structure stability key layer of floor and the key layer of failure and penetration in the floor reinforced by grouting is studied,and the model of“two key layers”is formed.The engineering criterion of 2 types and 7 factors that affecting the water control capacity of the“two key layers”is proposed,and the engineering research is carried out in Jiaozuo Mining Area.The results show that the strength of rock mass increases by 40%-159%after grouting,and the maximum tensile strength and shear strength of rock mass reach 5.78 MPa and 38.31 MPa respectively,the floor deformation is reduced,thus reducing the damage and penetration degree of the floor,reaching the engineering criterion of the key layer for the stability and water control of the floor structure.The failure of the key layer of water control through penetration plays a filling and inhibiting role in fracture development,which can prevent confined water inrush.Meanwhile,the insufficient effective waterproof thickness and fault reactivation are the main reasons for the water control failure of the“double key layer”.
关 键 词:底板“双关键层” 注浆加固 微震监测 断层活化 底板突水
分 类 号:TD745[矿业工程—矿井通风与安全]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.116.165.143