九开关逆变器供电的双Y移30°PMSM开路故障诊断  

Open Circuit Fault Diagnosis Method for Dual Y Shift 30 Degrees PMSM Supplied by Nine-switch Converter

在线阅读下载全文

作  者:刘陵顺 李永恒 葛宝川 LIU Lingshun;LI Yongheng;GE Baochuan(Institute of Aviation Basic,Naval Aviation University,Yantai Shandong 264001,China;The 92781th Unit of PLA,Sanya Hainan 572029,China)

机构地区:[1]海军航空大学航空基础学院,山东烟台264001 [2]92781部队,海南三亚572029

出  处:《微电机》2023年第5期47-52,共6页Micromotors

基  金:国家自然科学基金资助项目(51377168)。

摘  要:本文在双Y移30°PMSM逻辑动态模型基础上,提出一种九开关变换器开关管开路故障诊断方法。建立九开关变换器开关管通断信号与电机相电压之间的逻辑关系,推导出电机驱动系统逻辑动态模型,通过逻辑动态模型提供的电压先验信息与含有故障信息的电压实际输出值比较,提取故障信息,可对任一开关管开路故障进行准确定位。A nine-switch converter open circuit fault diagnosis method was proposed based on dual Y shift 30 degrees PMSM logic dynamic model.The logical relationship between switch on-off signal of nine-switch converter and motor phase voltage was established,and then logic dynamic model of motor drive system was derived.The voltage prior information provided by logic dynamic model was compared with the voltage actual output value containing fault information.By extracting fault information,one switch tube open circuit fault can be accurately located.

关 键 词:九开关逆变器 双Y移30°PMSM 故障诊断 