LNG接收站海水泵房进水流道长度水力特性试验研究  被引量:2

Experimental research on hydraulic characteristics of flow channel length of seawater pump house in LNG terminal

在线阅读下载全文

作  者:吴树铭 马进荣[1] 邹国良[1] 郭雅琼[1] WU Shuming;MA Jinrong;ZOU Guoliang;GUO Yaqiong(Key Laboratory of Port,Waterway and Sedimentation Engineering of Ministry of Transport,Nanjing Hydraulic Research Institute,Nanjing 210024,China)

机构地区:[1]南京水利科学研究院港口航道泥沙工程交通行业重点实验室,南京210024

出  处:《工业用水与废水》2023年第3期37-41,53,共6页Industrial Water & Wastewater

基  金:中央级公益性科研院所基本科研业务费专项资金资助项目(Y220003,Y220014)。

摘  要:沿海LNG接收站海水泵房取水的稳定性关系到开架式气化器的正常运行。海水泵房内水流传播途径复杂,在确保良好进水条件的前提下,减小进水流道长度能有效降低工程造价。对某LNG接收站海水泵房进行了水力特性模型试验,研究表明其吸水池长度(13.43D,D为吸水喇叭口直径)设计有较大冗余,提出了减小吸水池长度至7.43D及优化各水泵布置位置的试验方案。经验证,优化试验方案的海水泵房流道内水力特性良好,能够确保海水泵的正常运行,且流道缩短后,有效地降低了泵房建设投资。Water intake stability is related to normal operation of open rack vaporizer in seawater pump house of coastal LNG terminal.The propagation path of water flow is complex in the seawater pump house;therefore,the building cost of the project can be effectively reduced by cutting down the flow channel length while ensuring good inlet conditions.An experiment of hydraulic characteristics of the seawater pump house in a LNG terminal was carried out,the study results showed that,the length of the sump(13.43D,D is the diameter of the inlet bell)is redundant in design.The experimental scheme that reducing the length of the sump to 7.43D and optimizing the arrangement of each pump was further proposed.It has been verified that the optimized design scheme has good hydraulic characteristics of flow channel of seawater pump house,which can ensure normal operation of seawater pump,more than that,the pump house construction investment is effectively reduced after the flow channel length is shortened.

关 键 词:LNG接收站 海水泵房 进水流道 吸水池长度 水力特性 

分 类 号:TU991.35[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象