梨园水电站技术供水减压阀失调原因分析及处理  

Cause Analysis and Treatment of Technical Water Supply Pressure Reducing Valve Maladjustment in Liyuan Hydropower Station

在线阅读下载全文

作  者:蓝晶 LAN Jing(Yunnan HuadianJinsha River Midstream Hydropower Development Co.,Ltd.,Liyuan Power Generation Branch,Lijiang 674100,China)

机构地区:[1]云南华电金沙江中游水电开发有限公司梨园发电分公司,云南丽江674100

出  处:《云南水力发电》2023年第6期15-17,共3页Yunnan Water Power

摘  要:梨园水电站技术供水系统通过减压阀采用自流减压方式主要供给机组及主变所需的冷却水,随着机组运行时间的增长,减压阀频繁出现不能自动调节技术供水流量及压力的现象,影响机组及主变冷却系统的稳定运行。通过对实际运行中各机组技术供水减压阀故障现象进行分析,结合检修进行现场排查,最终查明并确认了减压阀失调的根本原因。并且通过提出针对性措施,显著提高了减压阀阀芯动作的准确及可靠性,保证了机组技术供水系统的安全稳定运行。The technical water supply system of LiyuanHydropower Station mainly supplies the cooling water required by the unit and the main transformer through the pressure reducing valve by gravity.With the growth of unit operation time,the phenomenon that the pressure reducing valve can not automatically adjust the flow and pressure of technical water supply frequently occurs,which affects the stable operation of the unit and the main transformer cooling system.Through the analysis of the failure phenomenon of the pressure reducing valve of the technical water supply of each unit in the actual operation,combined with the on-site troubleshooting,the root cause of the pressure reducing valve imbalance was finally identified and confirmed.Through the proposed targeted measures,the accuracy and reliability of the action of the pressure reducing valve core are significantly improved,and the safe and stable operation of the technical water supply system of the unit is ensured.

关 键 词:水电站 技术供水 减压阀 失调 

分 类 号:TV674[水利工程—水利水电工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象