检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李文彬 李志宇 战麒羽 Li Wen-bin;Li Zhi-yu;Zhan Qi-yu(Henan Diesel Engine Industry Co.,Ltd,Henan Luoyang 471003)
机构地区:[1]河南柴油机重工有限责任公司,河南洛阳471003
出 处:《内燃机与配件》2023年第11期99-101,共3页Internal Combustion Engine & Parts
摘 要:当两套或多套发电机组排气系统连接在一起时,若排气系统设计不合理,排气及在排气管形成的冷凝水会倒流进入未运行机组排气门处于打开状态的气缸内,最终导致燃烧室内形成大量冷凝水,冷凝水通过活塞与缸套之间的缝隙渗漏至油底壳导致机油乳化等问题。本文针对该问题提出了一种排气系统设计方案,经现场试验验证,能够有效解决上述问题,并为其他类似应用提供设计参考。When two or more gensets exhsust system is connected together,if the exhaust system is not designed properly,the exhaust and condensate water in the exhaust pipe will flow back into the combustion chamber of the unoperated genset,a large amount of condensate water is formed,which leakage through the gap between the piston and the cylinder liner to the oil sump,eventually lead to the oil emulsification and other problems.This paper presents a design scheme of exhaust system for this problem,through field test verification,which can effectively solve the problem,and provide references for other similar applications.
分 类 号:U464.134.4[机械工程—车辆工程]