Haemoglobin Measurement from Eye Anterior Ciliary Arteries through Borescope Camera  

在线阅读下载全文

作  者:Mohamed Abbas Ahamed Farook S.Rukmanidevi N.R.Shanker 

机构地区:[1]Department of Electronics and Communication Engineering,Vel Tech Multi Tech Dr Rangarajan Dr Sakunthala Engineering College,Chennai,600062,India [2]Department of Electronics and Communication Engineering,R.M.D Engineering College,Chennai,601206,India [3]Department of Computer Science and Engineering,Aalim Muhammed Salegh College of Engineering,Chennai,600055,India

出  处:《Computer Systems Science & Engineering》2023年第2期1763-1774,共12页计算机系统科学与工程(英文)

摘  要:Nowadays,smartphones are used as self-health monitoring devices for humans.Self-health monitoring devices help clinicians with big data for accurate diagnosis and guidance for treatment through repetitive measurement.Repetitive measurement of haemoglobin requires for pregnant women,pediatric,pulmonary hypertension and obstetric patients.Noninvasive haemoglobin measurement through conjunctiva leads to inaccurate measurement.The inaccuracy is due to a decrease in the density of goblet cells and acinar units in Meibomian glands in the human eye as age increases.Furthermore,conjunctivitis is a disease in the eye due to inflammation or infection at the conjunctiva.Conjunctivitis is in the form of lines in the eyelid and covers the white part of the eyeball.Moreover,small blood vessels in eye regions of conjunctiva inflammations are not visible to the human eye or standard camera.This paper proposes smartphone-based hae-moglobin(SBH)measurement through a borescope camera from anterior ciliary arteries of the eye for the above problem.The proposed SBH method acquires images from the anterior ciliary arteries region of the eye through a smartphone attached with a high megapixel borescope camera.The anterior ciliary arteries are projected through transverse dyadic wavelet transform(TDyWT)and applied with delta segmentation to obtain blood cells from the ciliary arteries of the eye.Furthermore,the Gaussian regression algorithm measures haemoglobin(Hb)with more accuracy based on the person,eye arteries,red pixel statistical parameters obtained from the left and right eye,age,and weight.Furthermore,the experimen-tal result of the proposed SBH method has an accuracy of 96%in haemoglobin measurement.

关 键 词:Hemoglobin measurement borescope camera SMARTPHONE anterior ciliary arteries region 

分 类 号:TP391.41[自动化与计算机技术—计算机应用技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象