检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈云飞 赵晨昊 魏占朋 CHEN Yunfei;ZHAO Chenhao;WEI Zhanpeng(Cable Branch of State Grid Tianjin Electric Power Company,Tianjin 300171,China)
机构地区:[1]国网天津市电力公司电缆分公司,天津300171
出 处:《山西电力》2023年第3期20-23,共4页Shanxi Electric Power
摘 要:有效检测出电缆户外终端局部放电对保障电缆线路稳定运行十分重要。在介绍高频局部放电检测原理的基础上,结合一起110 kV户外终端典型案例,通过对检测数据的分析,详细论述了在户外终端应用高频局部放电检测进行局部放电信号判别和定位的方法。此外,通过对多起案例检测数据的分析并结合解体检查的结果,总结了户外终端局部放电检测的相关经验。It is very important to detect the partial discharge(PD)of outdoor cable terminal effectively to ensure the stable operation of cable lines.Based on an introduction of the principle of high-frequency PD detection,the method of identifying and locating PD signal by high-frequency PD detection in outdoor terminal is discussed in detail combined with an analysis of the detection data of a typical case of 110 kV outdoor terminal.In addition,the relevant experience of outdoor terminal PD detection is summarized on the basis of an analysis of the test data from multiple similar cases and the results of disintegration examination.
分 类 号:TM855[电气工程—高电压与绝缘技术]