摘 要:介绍了实验室的通风特点,阐述了实验室的冷热源的配置和水系统、风系统的设计。通过重点论述实验室的负压控制和整体实验区的压差梯度的控制,得到空调通风系统的计算和变风量系统的自动控制是保障实验室安全运行的重要措施的结论。The ventilation characteristics of the laboratory are introduced.The configuration of the chillers and boilers and the design of water system and air system in the laboratory are described.By focusing on the negative pressure control in the laboratory and the control of the differential pressure gradient in the whole experimental area,it is concluded that the calculation of the air conditioning and ventilation system and the automatic control of the variable air volume system are important measures to ensure the safe operation of the laboratory.