检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郝郁 黄向玫[1] 刘熙罡 李波[1] 李伟[1] HAO Yu;HUANG Xiang-mei;LIU Xi-gang;LI Bo;LI Wei(Southwestern Institute of Physics,Chengdu 610041)
出 处:《核聚变与等离子体物理》2023年第2期169-174,共6页Nuclear Fusion and Plasma Physics
摘 要:利用计算流体力学分析软件ANSYSCFX,对气体注入系统的检漏系统中氚监测支路气体流量进行了数值模拟,发现在支管管径1/2in且与主管夹角成90°的情况下,当主路流量为33m^(3)·h^(-1)时,支管进气量只有0.2354m^(3)·h^(-1),不满足0.36~3.6m^(3)·h^(-1)的设计要求。采取改变支管与主管之间的夹角和增大支管管径两种方式对支路结构进行了优化。优化后的结果显示,将支管内半径增大至6.9mm以上或减小支管与主管的夹角至30°以下均可使检漏管路满足各工况下的进气量要求。Based on the computational fluid dynamics analysis software ANSYS CFX,the gas flow of tritium monitoring branch in leak detection system of gas injection system(GIS)is simulated.It is found that the branch structure with half inches and 90 degrees cannot meet the demand of branch pipe air flow detection.Therefore,the structure is optimized by changing the angle between the bypass pipe and the main pipe or increasing the diameter of the branch pipe.The optimized results show that increasing the inner radius of the branch pipe to more than 6.9mm or reducing the included angle to less than 30°can make the leak detection pipeline meet the requirements of air inlet under various working conditions.
关 键 词:数值模拟 ANSYS CFX 支管进气量 结构优化
分 类 号:TL626[核科学技术—核技术及应用]